Technical specifications |
63
Product number
100000002
Power dissipation
8 W
Maximum elevation
≤ 2,000 m AMSL
Dimensions (H × W × D)
515 × 428 × 145 mm (width without overhangs: 395 mm)
Weight per wallbox
Approx. 10.5 kg
The Wallbox eM4 Twin Controller is also available as a variant with a shutter charging socket. In addition, all variants
of the Wallbox eM4 Twin Controller are available as reev ready variants, which are ready for operation with the back-
end solutions from reev. The basic technical data are identical in each case; the corresponding product numbers can
be found in the following table:
Controller with shutter
Controller with Shutter and reev ready
100000023
100000184
eM4 Twin Extender series
Product number
100000004
Rated voltage
230/400 V
Rated frequency
50 Hz
Rated current
32 A
Maximum output
2 × 11 kW or 1 × 22 kW
Connection system
Type 2 charging socket, 2 pcs.
Phase system
3-phase (reconfigurable to 1-phase)
Terminal blocks
Direct connection to the terminal block, supply cables up
to a maximum of 10 mm² or cable diameters ≤ 25 mm
Upstream fuse
32 A (required onsite), C characteristic recommended
Rated insulation voltage (Ui)
4 kV
Rated impulse voltage (Uimp)
4 kV
Rated impulse withstand current (Ipk)
6 kA
Rated short-time withstand current (Icw)
5 kA
Conditional rated short-circuit current (Icc)
6/10 kA
Rated diversity factor (RDF)
1.0
Residual current circuit breaker for each
charge point
RCCB, Type A, 30 mA
DC residual current detection for each
charge point
DC-RCM, I
Δn d.c.
≥ 6 mA
Overcurrent protection for each charge point
Integrated into firmware, disconnection at 125% after 10 seconds
Energy meter per charge point
MID compliant
Load switching for each charge point
Installation contactor, 4-pole, 40 A
Weld detection
No charging possible with welded contactors
Temperature monitoring
Internal, charging current reduction or shut down
Optional ventilation function of the vehicle
Not supported
RFID standard
ISO14443A/B, UID only (4-byte/7-byte), ISO 15693 and ISO 18092
Access control
RFID, QR code or smartphone app
Backend communication
Via Controller wallbox
Supported protocols for external systems
OCPP 1.5 + 1.6, OCPP Smart Charging, Modbus TCP
Communication Controller
LAN, WLAN
Load shedding / external release contact
Terminal for connecting a control cable,
e.g. in accordance with VDE-AR-N 4100