126 Technical data
Temperature rating of types-0500kW-A, -0875kW-B and -1000kW-C
This curve shows the load capacity of inverter types -0500kW-A, -0875kW-B and -
1000kW-C as a function of ambient temperature. The curve is applicable at altitudes below
1000 m (3300 ft).
With temperature compensated altitude derating
Each degree of maximum ambient temperature below the nominal ambient temperature
gives a compensation to the altitude derating, but the temperature derating curve and
maximum allowed altitude must not be exceeded. When calculating the compensated
altitude derating factor, you must observe the corner points of the temperature rating
curves.
Example1: For inverter types PVS800-57-0100kW-A and PVS800-57-0250kW-A installed
at 1800 m (5900 ft), if the maximum ambient temperature is limited to +35 °C (95 °F), the
compensated altitude derating factor is 100% - 8 · 1% + (40 - 35) · 1% = 97% or 0.97.
Example 2: For inverter types PVS800-57-0315kW-B, PVS800-57-0630kW-B installed at
2100 m (6890 ft), if the maximum ambient temperature is limited to +35 °C (95 °F), the
compensated altitude derating factor is 100% - 11 · 1% + (45 - 35) · 0.5% = 94% or 0.94.
Example 3: For inverter types PVS800-57-0500kW-A, PVS800-57-0875kW-B and
PVS800-57-1000kW-C installed at 2800 m (9200 ft), if the maximum ambient temperature
is limited to +32 °C (89 °F), the compensated altitude derating factor is 100% -
18 · 1% + (50 - 45) · 1.6% + (45 - 32) · 0.6% = 97.8% or 0.978.
T
100
90
+35 °C
+95 °F
+55 °C
+131 °F
80
+45 °C
+113 °F
+25 °C
+77 °F
+
15 °C
+
59 °F
110
%
120
...
...
0
+60 °C
+140 °F
-15 °C
+5 °F
Nominal ambient temperature
108
Summary of Contents for PVS800-57-0100kW-A
Page 1: ...ABB solar inverters Hardware manual PVS800 57 central inverters 100 to 1000 kW ...
Page 4: ......
Page 22: ...20 Safety instructions ...
Page 64: ...62 Operation principle and hardware description ...
Page 74: ...72 Mechanical installation ...
Page 90: ...88 Electrical installation PE PE PE ...
Page 124: ...122 Maintenance ...
Page 152: ...150 Dimension drawings Frame R7i 3AUA0000083128 ...
Page 153: ...Dimension drawings 151 AC output 3AUA0000083128 ...
Page 154: ...152 Dimension drawings 3AUA0000083128 One DC input Four DC inputs ...
Page 156: ...154 Dimension drawings R8i 8 DC inputs option 8H382 3AXD50000016935 ...
Page 157: ...Dimension drawings 155 R8i AC output terminals 3AXD50000016935 ...
Page 165: ...Dimension drawings 163 2 R8i AC output terminals 3AXD50000015007 ...
Page 173: ...Dimension drawings 171 3 R8i AC input terminals 3AXD50000015006 ...
Page 178: ...176 Dimension drawings ...
Page 180: ...Contact us www abb com solar 3AUA0000053689 Rev H EN EFFECTIVE 2014 07 09 ...