![ABB IRB 6700 Series Product Manual Download Page 167](http://html1.mh-extra.com/html/abb/irb-6700-series/irb-6700-series_product-manual_3662281167.webp)
Note
Action
xx1200000952
Remove the plug from the vent hole.
WARNING
Open the vent hole while using the dis-
penser, to avoid damaging vital parts in the
gear.
5
Suck out the oil with the oil dispenser.
Note
There will be some oil left in the gear after
draining.
6
WARNING
Used oil is hazardous material and must
be disposed of in a safe way. See section
for more in-
formation.
7
Vent hole plug, tightening torque: 24 Nm.
Refill oil or:
1
Remove the oil dispenser
2
Refit the protective cap on the
nipple.
3
Refit the vent hole plug.
8
Filling oil into the axis-2 gearbox
Use this procedure to refill the gearbox with oil.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
1
Continues on next page
Product manual - IRB 6700
167
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
3 Maintenance
3.4.3 Changing oil, axis-2 gearbox
Continued