![ABB IRB 6700 Series Product Manual Download Page 582](http://html1.mh-extra.com/html/abb/irb-6700-series/irb-6700-series_product-manual_3662281582.webp)
Note
Action
xx1300001113
Refit the axis-6 motor cables by carefully
pushing them and the carrier into position.
8
xx1300000485
Tighten the M4 screw that holds the carrier.
Note
The screw is located at the bottom of the
carrier.
9
xx1300000484
Refit the cable bracket.
10
See
Performing a leak-down test on
Perform a leak-down test.
11
Disconnect the 24 V DC power supply.
12
Continues on next page
582
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.7.6 Replacing the axis-6 motor
Continued