Note
Action
xx1300000730
Remove the screws and washers that secure the SMB
unit bracket.
3
xx1300000728
Pull out the SMB unit a little and disconnect the con-
nectors from the SMB board:
•
R1.SMB1-3, R1.SMB4-6 and R2.SMB
•
Battery cable connector R2.G.
Disconnect the battery cable by pressing down
the upper lip of the R2.G connector to release
the lock while pulling the connector upwards.
4
xx1700000993
xx1300000731
Pull out the SMB unit and put it in an ESD bag.
5
Refitting the SMB unit
Refitting the SMB unit
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.