![ABB IRB 6700 Series Product Manual Download Page 237](http://html1.mh-extra.com/html/abb/irb-6700-series/irb-6700-series_product-manual_3662281237.webp)
Note
Action
xx1300000485
Unscrew the M4 screw that holds the carri-
er.
Note
The screw is located at the bottom of the
carrier.
5
xx1300001113
Pull out the carrier from its position.
6
xx1300000666
Pull out the axis-6 motor cables by holding
the cables with one hand at the motor and
the other at the carrier.
7
Disconnecting the axis-5 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Continues on next page
Product manual - IRB 6700
237
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness
Continued