Required consumables
Note
Article number
Consumable
-
Cable straps
Installing the cooling fan
Use these procedures to install the cooling fan.
Installing the fan
Note
Action
Move the robot to its synchronization position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
2
xx1800000157
Remove the metal sheet frame from the fan unit
assembly by loosening the six screws.
3
xx1800000159
Loosen the two tightening screws so they don´t
damage the motor surface during installation.
4
Continues on next page
104
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
2 Installation and commissioning
2.7.2 Installing the motor cooling fan (option)
Continued