Note
Action
O-ring, nitrile rubber: 3HAB3772-57
xx2100001136
Only for floor-mounted robot
Refit the sealing ring. Verify that the o-ring
is undamaged and placed in its groove on
the sealing ring.
Replace if damaged.
11
Refitting the protection tube
Note
Action
xx2100002214
Floor-mounted robot:
Lift the protection tube and secure with the two
screws from below.
1
Torx pan head screw: M6x16 A4-
80 (2 pcs)
xx2100002493
Option Inverted (3317-1)
:
Refit the adapter with the attachment screws.
2
Continues on next page
Product manual - IRB 5720
209
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the axis-1 cassette sealing
Continued