Note
Action
xx2100001255
Remove the arm house cover screws.
5
xx2100001256
Fit the M12 bolt and rotate it to press out the
complete cover.
6
xx2100001286
Remove the complete cover.
Remove and save the oil plugs for refitting on the
new cover.
WARNING
Oil residues will drip out during removal.
Make sure that protective gear like goggles and
gloves are always worn.
WARNING
Handling gearbox oil involves several safety risks,
see
Gearbox lubricants (oil or grease) on page 29
7
WARNING
Used oil is hazardous material and must be dis-
posed of in a safe way. See
for more information.
Remove the tool from the arm house cover. The
tool on the tube shaft can stay fitted.
8
Refitting the arm house cover including the cassette sealing
Use these procedures to refit the arm house cover including the cassette sealing.
Preparations before refitting the arm house cover
Note
Action
Wipe clean all contact surfaces.
1
Continues on next page
224
Product manual - IRB 5720
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the arm house cover including the axis-4 cassette sealing
Continued