6.1.3 When to calibrate
When to calibrate
The system must be calibrated if any of the following situations occur.
The resolver values are changed
If resolver values are changed, the robot must be re-calibrated using the calibration
methods supplied by ABB. Calibrate the robot carefully with standard calibration,
according to information in this manual.
If the robot has
absolute accuracy
calibration, it is also recommended, but not
always necessary to calibrate for new absolute accuracy.
The resolver values will change when parts affecting the calibration position are
replaced on the robot, for example motors or parts of the transmission.
The revolution counter memory is lost
If the revolution counter memory is lost, the counters must be updated. See
Updating revolution counters on page 563
. This will occur when:
•
The battery is discharged
•
A resolver error occurs
•
The signal between a resolver and measurement board is interrupted
•
A robot axis is moved with the control system disconnected
The revolution counters must also be updated after the robot and controller are
connected at the first installation.
The robot is rebuilt
If the robot is rebuilt, for example, after a crash or when the reach ability of a robot
is changed, it needs to be re-calibrated for new resolver values.
If the robot has
absolute accuracy
calibration, it needs to be calibrated for new
absolute accuracy.
Robot is not floor mounted
The original calibration data delivered with the robot is generated when the robot
is floor mounted. If the robot is not floor mounted, then the robot accuracy could
be affected. The robot needs to be calibrated after it is mounted.
560
Product manual - IRB 5720
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
6 Calibration
6.1.3 When to calibrate
Summary of Contents for IRB 5710
Page 1: ...ROBOTICS Product manual IRB 5720 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 580: ...This page is intentionally left blank ...
Page 604: ...This page is intentionally left blank ...
Page 609: ......