Removing the brake release unit
Use this procedure to remove the brake release unit.
Removing the electronic box
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded space.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
read the safety information in section
2
xx2100002134
Remove the electronic box screws.
3
xx2100002135
Remove the electronic box, including all internal
equipment.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
4
Disconnecting and removing the SMB unit
Note
Action
DANGER
Make sure that all supplies for electrical power, hy-
draulic pressure, and air pressure are turned off.
1
Continues on next page
Product manual - IRB 5720
307
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.7.3 Replacing the brake release unit
Continued