Ex relevant specifications
96
FV4000 / FS4000
D184B097U02
11 Ex relevant specifications
11.1 General ex relevant specifications
11.1.1 HART devices
Models designed for hazardous areas with ATEX / IECEx approval
Models
Approvals
VT41 / ST41 / VR41 / SR41 • Operation in Zone 1:
Ex ib IIC (intrinsically safe supply)
• Operation in Zone 2:
Ex nA [nL] IIC (non-intrinsically safe supply)
• Operation in Zone 21 / 22:
Ex tD A21 / Ex tD A22 (non-intrinsically safe supply or
intrinsically safe supply)
Important
All types of protection are noted on the name plate.
Flowmeters operating in Category 3 (Zone 2 / 22) may subsequently be operated in Category
2 (Zone 1 / 21) without modification.
The respective applicable maximum values must be complied with.
Models
Approvals
VT42 / ST42 / VR42 / SR42 • Operation in Zone 1:
Ex d [ib] IIC (non-intrinsically safe supply)
• Operation in Zone 1:
Ex ib IIC (intrinsically safe supply)
• Operation in Zone 2:
Ex nA [nL] IIC (non-intrinsically safe supply)
• Operation in Zone 21 / 22:
Ex tD A21 / Ex tD A22 (non-intrinsically safe supply or
intrinsically safe supply)
Important
All types of protection are noted on the name plate. In the case of operation in Zone 1, the
user specifies the type of protection by means of the type of supply.
Flowmeters operated in Category 3 (Zone 2) may subsequently be operated in Category 2
(Zone 1) without modification. Within Category 2, the Ex d [ib] design may subsequently be
operated as EX ib without modification.
The respective applicable maximum values must be complied with. The significant differences
between models are listed in the table titled "Differences between explosion-proof designs with
regard to safety engineering". Detailed descriptions appear later in this section.
Summary of Contents for FS4000
Page 1: ...Operating Instruction D184B097U02 Vortex Flowmeter Swirl Flowmeter FV4000 FS4000 ...
Page 116: ...Appendix 116 FV4000 FS4000 D184B097U02 ...
Page 117: ...Appendix D184B097U02 FV4000 FS4000 117 ...
Page 118: ...Appendix 118 FV4000 FS4000 D184B097U02 ...
Page 119: ...Appendix D184B097U02 FV4000 FS4000 119 ...
Page 120: ...Appendix 120 FV4000 FS4000 D184B097U02 ...
Page 125: ......