DCS500 Pin and Parameter list
A 20
EMF_FILT_TC
Parameter of SETTINGS-function block.
( S2/16 )
Filter time constant for calculated EMF before EMF-controller.
513
FB_P: I2
SC: 1
HL: 10000
LL: 0
D: 10
U: ms
EARTH.CURR_SEL
Parameter of CONVERTER_PROTECTION-function block.
( S9/16 )
Selection for earth fault monitoring:
0 = DISABLE
1 = ENABLE.
514
FB_P: E2
SC: -
HL: 1
LL: 0
D: 0
U: -
EARTH.FLT_LEV
Parameter of CONVERTER_PROTECTION-function block.
( S9/16 )
Earth fault current tripping level in amperes.
515
FB_P: I2
SC: 1
HL: 20
LL: 0
D: 4
U: A
EARTH.FLT_DLY
Parameter of CONVERTER_PROTECTION-function block.
( S9/16 )
The time after the earth fault is activated.
516
FB_P: I2
SC: 1
HL: 10000
LL: 0
D: 10
U: ms
SET_I_CONV_A
Parameter of SETTINGS-function block.
( S2/16 )
The nominal current of the converter.
Note:
This parameter overwrites the nominal current of the converter defined by
type code resistors !
0 = type code resistors are in use
> 0 = value of this parameter is used.
517
FB_P: I2
SC: 1
HL: 10000
LL: 0
D: 0
U: A
SET_U_CONV_V
Parameter of SETTINGS-function block.
( S2/16 )
The nominal voltage of the converter.
Note:
This parameter overwrites the nominal voltage of the converter defined by
type code resistors !
0 = type code resistors are in use
> 0 = value of this parameter is used.
518
FB_P: I2
SC: 1
HL: 2000
LL: 0
D: 0
U: V
SET_MAX_BR_TEMP
Parameter of SETTINGS-function block.
( S2/16 )
The tripping level for the converter heat sink temperature monitoring.
Note:
This parameter overwrites the max bridge temperature of the converter defined by
type code resistors !
0 = type code resistors are in use
> 0 = value of this parameter is used.
519
FB_P: I2
SC: 1
HL: 150
LL: 0
D: 0
U: C