DCS500 Pin and Parameter list
A 57
Group 23: TORQUE and CURRENT LIMITS
[SPC_TORQ_MAX]
Input of TORQUE/CURRENT_LIMITATION-function block.
( S6/16 )
Maximum torque limit for the speed controller.
Can be connected to analog input or function block output.
2301
FB_I: C4
SC: TORQ
HL: 19999
LL: 0
D: 12510
U: -
[SPC_TORQ_MIN]
Input of TORQUE/CURRENT_LIMITATION-function block.
( S6/16 )
Minimum torque limit for the speed controller.
Can be connected to analog input or function block output.
2302
FB_I: C4
SC: TORQ
HL: 19999
LL: 0
D: 12511
U: -
[TREF_TORQ_MAX]
Input of TORQUE/CURRENT_LIMITATION-function block.
( S6/16 )
Maximum torque limit for the torque reference chain.
Can be connected to analog input or function block output.
2303
FB_I: C4
SC: TORQ
HL: 19999
LL: 0
D: 12510
U: -
[TREF_TORQ_MIN]
Input of TORQUE/CURRENT_LIMITATION-function block.
( S6/16 )
Minimum torque limit for the torque reference chain.
Can be connected to analog input or function block output.
2304
FB_I: C4
SC: TORQ
HL: 19999
LL: 0
D: 12511
U: -
TORQ_MAX
Parameter of TORQUE/CURRENT_LIMITATION-function block.
( S6/16 )
Maximum torque limit for the drive.
2305
FB_P: I2
SC: TORQ
HL: 16000
LL: 20
D: 4000
U: %
TORQ_MIN
Parameter of TORQUE/CURRENT_LIMITATION-function block.
( S6/16 )
Minimum torque limit for the drive.
2306
FB_P: I2
SC: TORQ
HL: -20
LL: -16000
D: -4000
U: %
ARM_CURR_LIM_P
Parameter of TORQUE/CURRENT_LIMITATION-function block.
( S6/16 )
Maximum current of the motor bridge.
2307
FB_P: I2
SC: MCURR HL: 16383
LL: 0
D: 4095
U: A
ARM_CURR_LIM_N
Parameter of TORQUE/CURRENT_LIMITATION-function block.
( S6/16 )
Maximum current of the generator bridge.
2308
FB_P: I2
SC: MCURR HL: 0
LL: -16383
D: -4095
U: A