Functional Software description
DCS 500 Software Description
3
Parameter values will be saved by means of the parameter
BACKUP STORE MODE (11202)
. When the action is finished af-
ter writing or reading of parameters the mode is changed to 0
[NONE].
BACKUPSTORE MODE:
0
=
[NONE]
no backup
1
=
[SAVE MOT1 SET]
save motor set 1 to FPROM memory.
2
=
[SAVE MOT2 SET]
save motor set 2 to FPROM memory.
3
=
[FACTORY SET VALUE]
default values are restored to the RAM
memory
4
=
[SELECT MOT1 SET]
read motor set 1 from the FPROM memory
5
=
[SELECT MOT2 SET]
read motor set 2 from the FPROM memory
Identification of
the Converter
Software version
The version of the software can be identified in two ways:
-
software version is printed on the label which is located on the
memory circuits D33.
-
the signal
CNT SW VERSION (11218)
indicates the converter
program version.
DC21.226
DCS500
VERSION
(226 = 1. version SDCS-CON-2)
(227 = 2. version)
Figure 3
Identification labels of memory circuit D33
Identification of
the Field Exciter
Software version
If a
field exciter module SDCS-FEX-2 or DCF 503/4 (SDCS-
FEX-3x)
is used the version of the field exciter software can be
identified in two ways:
-
software version is printed on a label on the micro controller of
the field supply unit SDCS-FEX-2 or DCF 503/4
-
the signal
FEXC1 SW VERSION (11220)
indicates the con-
verter program version.
when two field exciter units are installed in the drive, the pro-
gram version of the second unit can be read from signal
FEXC2
SW VERSION (11221)
.
All the parameters of two-phase field exciter units are stored in the
FPROM memory circuit (D35) of the converter.