03 POWER ELECTRONICS AND CABINET FEATURES
3BHS213401 E01 REV H
ACS1000 AIR-COOLED
USER MANUAL
3.4.9.3
External cooling for braking resistors
A digital output and a digital input can be used to control and monitor an external cooling fan
or pump for the braking resistors.
3.4.9.4
Braking chopper ratings
The maximum braking power is limited to 60% of the nominal power of the ACS1000 and must
not be greater than 2.5 MW (Tab. 2-1).
The relation between maximum braking energy (E
brake max
) and maximum chopper braking
power (P
chopper max
) is as follows:
After a braking period of 30 s with maximum braking power (2.5 MW), a cooling time of one
hour is required. If two braking sequences of 30 s are necessary within an hour, the maximum
braking power has to be reduced to 50% of the maximum possible braking power.
Table 3-1: Braking ratings
ACS1000
Braking chopper
Type
Max. DC-link
voltage (V)
Max. braking power
(MW)
Max. braking
power (MW)
Max. braking
energy (MW)
ACS1012-A1
ACS 1013-A1
ACS 1014-A1
4200
6000
7270
0.426
0.426
0.426
2500
75
ACS1012-A2
ACS 1013-A2
ACS 1014-A2
4200
6000
7270
0.672
0.672
0.840
2500
75
ACS1012-A3
ACS 1013-A3
ACS 1014-A3
4200
6000
7270
0.960
1.080
0.960
2500
75
ACS1012-W1
ACS 1013-W1
ACS 1014-W1
4200
6000
7270
1.350
1.500
1.350
2500
75
ACS1012-W2
ACS 1013-W2
ACS 1014-W2
4200
6000
7270
1.680
2.130
2.130
2500
75
ACS 1013-W3
ACS 1014-W3
6000
7270
2.500
2.500
2500
75
E
brake max
MWs
P
chopper max
MW
30 sec
=
Summary of Contents for ACS 1013-A1
Page 1: ... MEDIUM VOLTAGE AC DRIVES ACS1000 air cooled User manual ...
Page 3: ...Contents ACS1000 air cooled User manual ...
Page 5: ... 01 About this manual 01 3 14 ...
Page 16: ......
Page 17: ... 02 Important safety information 02 15 26 ...
Page 28: ......
Page 29: ... 03 Power electronics and cabinet features03 27 50 ...
Page 53: ... 04 Control system 04 51 66 ...
Page 68: ......
Page 69: ... 05 Transportation storage and disposal05 67 74 ...
Page 76: ......
Page 77: ... 06 Mechanical installation 06 75 82 ...
Page 84: ......
Page 85: ... 07 Electrical installation07 83 106 ...
Page 108: ......
Page 109: ... 08 Commissioning 08 107 112 ...
Page 115: ... 09 Operation 09 113 126 ...
Page 129: ... 10 CDP control panel 10 127 150 ...
Page 153: ... 11 Preventive and corrective maintenance 11 151 182 ...
Page 185: ......