59
6.1.2.
Weighing history output example
The format of the weighing history that is output to the USB memory is as follows
“Date, time (hour : minute : second, 10 millisecond), product No., weighing result, judgment”
The output example is shown below.
Fig.60 Weighing history output example
Description of the output judgment results is shown below.
Judgment results
Description
OK Passed
Over Overweight
Under Underweight
Detect Two
The next product is conveyed to the weighing conveyor before the
weighing value of the previous product is confirmed.
Unsplit
The product length is longer than the specified product length.
Metal Metal
detected
Ext
1 External
1
Ext
2 External
2
Date
Tim
10 millisecond
Group No.
Product
Weighing
result
Judgment