35
1. Touch the DO Behavior button of the setting menu to open the screen below.
Touch the Left arrow key or Right arrow key to switch the judgment items.
Fig.31 DO Behavior Setting screen
2. Select Delay Time to enter a delay time for each DO.
e.g.: connecting DO1 to the flipper type rejector
A basic delay time is the time a product moves from the weighing conveyor to the rejector.
Fig.32 Delay time setting example
When the distance from the weighing conveyor to the rejector is 0.2 m and the belt speed is 30 m/min, the DO1
delay time will be 0.4 second. (0.2 m
÷
30 m/min x 60 s = 0.4 s)
Note that the delay time may need to be fine adjusted depending on the swing time (setting of the speed
controllers) of the rejector flipper arms.
3. Select Hold Time to enter a hold time for each DO.
Product
Weighing conveyor
Rejector
Delay time [s]