Chapter 56 VLAN
OLT2406 User’s Guide
441
the default VID of the ingress port is given as the VID of the frame. Of the 4096 possible VIDs, a VID of 0 is
used to identify priority frames and the value 4095 (FFF) is reserved, so the maximum possible number of
VLAN configurations is 4,094.
56.3.1 Forwarding Tagged and Untagged Frames
Each port on the OLT is capable of passing tagged or untagged frames. To forward a frame from an
802.1Q VLAN-aware switch to an 802.1Q VLAN-unaware switch, the OLT first decides where to forward
the frame and then strips off the VLAN tag. To forward a frame from an 802.1Q VLAN-unaware switch to
an 802.1Q VLAN-aware switch, the OLT first decides where to forward the frame, and then inserts a
VLAN tag reflecting the ingress port's default VID. The default PVID is VLAN 1 for all ports, but this can be
changed.
A broadcast frame (or a multicast frame for a multicast group that is known by the system) is duplicated
only on ports that are members of the VID (except the ingress port itself), thus confining the broadcast to
a specific domain.
56.4 Static VLAN
Use a static VLAN to decide whether an incoming frame on a port should be
• sent to a VLAN group as normal depending on its VLAN tag.
• sent to a group whether it has a VLAN tag or not.
• blocked from a VLAN group regardless of its VLAN tag.
You can also tag all outgoing frames (that were previously untagged) from a port with the specified
VID.
56.5 VLAN Configuration Overview
1
Use the
vlan <
vlan-id
>
command to configure or create a VLAN on the OLT. The OLT automatically
enters config-vlan mode. Use the
exit
command when you are finished configuring the VLAN.
2
Use the
interface port-channel <
aid
>
command to set the VLAN settings on a port. The OLT
automatically enters config-interface mode. Use the
pvid <
vlan-id
>
command to set the VLAN ID
you created for the port-list in the PVID table. Use the
exit
command when you are finished configuring
the ports.
Note: The OLT will always configure the ONT to send out US packets with VLAN tag. The PON
port must always be configured as egress tagged.
TPID
2 Bytes
User Priority
3 Bits
CFI
1 Bit
VLAN ID
12 bits
Содержание OLT2406
Страница 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Страница 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Страница 33: ...33 PART I Introduction and Hardware Installation...
Страница 62: ...Chapter 3 Maintenance OLT2406 User s Guide 62 Figure 36 Slide the Power Module In and Tighten the Thumbscrews...
Страница 63: ...63 PART II Web Configurator...
Страница 118: ...Chapter 9 VLAN OLT2406 User s Guide 118 Figure 74 Advanced Application VLAN VLAN Status Static VLAN...
Страница 138: ...Chapter 14 Spanning Tree Protocol OLT2406 User s Guide 138 Figure 86 Advanced Application Spanning Tree Protocol MSTP...
Страница 161: ...Chapter 18 Link Aggregation OLT2406 User s Guide 161 Your trunk group 1 T1 configuration is now complete...
Страница 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Страница 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Страница 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...
Страница 210: ...Chapter 25 Multicast OLT2406 User s Guide 210 Figure 126 Advanced Application Multicast Multicast Setting MVR...
Страница 248: ...Chapter 28 Loop Guard OLT2406 User s Guide 248 Figure 151 Advanced Application Loop Guard...
Страница 393: ...393 PART III CLI Commands...
Страница 581: ...Chapter 78 VoIP OLT2406 User s Guide 581...
Страница 725: ...725 PART IV Troubleshooting Specifications Appendices and Index...