61
10.2 Coded Zfx Synchronizer
With the help of a coded Zfx Synchronizer, no further alignment actions are required and thus the error rate can
be reduced.
The determination of what is to be scanned and how takes place in Zfx Manager 2.0, from which the scan is usually started.
Settings in Zfx Manager 2.0
Scanning example:
Entry in Zfx Manager 2.0:
×
Open new order
×
Enter order data
The order may appear as follows:
×
Reduced coping: Tooth 11
×
Anatomical crown: Tooth 16
×
Antagonist: Teeth 41 / 46
×
Adjacent teeth: Teeth 12 / 21 and 15 / 17
Select antagonist type: Virtual articulator
Save order
Start scan by clicking the Scan button
The scan program is started by clicking the scan button in Zfx Manager 2.0. The user interface for scanning mode as
described in
→
Chapter 4.5 “Operating mode – Scan” appears.
Step 1 / 3 – Whole jaw model scan
×
Insert the Zfx Synchronizer with the full jaw model fitted
×
See the description of the Zfx Synchronizer for how to fit
the jaw model in the synchronizer
Start the scan by clicking the
”Scan”
button
×
Adjust the brightness (
→
×
Define the scan area (
→
×
Select the setting plane
(Frankfurt horizontal or Camper plane)
Start the scan by clicking the right
”arrow button”