163
Configuring a Console
Table 67: S4000 Option Code Definition
Some options require purchasing. To inquire about changing options to a Series 4000
console already in service, please contact Zetron’s Customer Service.
Common Control Data Rate
The rate of the data between the console and the CCE is selectable between high (9600
Baud) and low (1200 Baud). Normally the high rate is used. However, for consoles that
are remotely controlled from the CCE by way of modems, the low rate should be used. Be
sure that the rate selected at the Console Interface Card inside the CCE matches that of the
associated console.
Option Code
Option Description
Default Condition
L
With ANI Linkage enabled, any
dispatcher can press ANI Review to
clear ANI from all consoles.
ANI Linkage Disabled. Every
dispatcher must press ANI Review to
clear the ANI information on their own
console.
B
The serial connection from the console
to the CIC is 1200 baud
The serial connection from the console
to the CIC is 9600 baud
D
D-PTT always selects the desk mic.
This option is required when using both
a desk mic and a gooseneck mic at the
same time.
A contact closure on D-PTT selects the
CPSW-defined dynamic input.
T
With ANI Transpond enabled, the
console transmits a short, audible beep
to indicate that it has received ANI.
ANI Transpond disabled.
X
Extended Paging enabled. This adds
several paging formats: Rotary Dial/
1500 Hz or 2805 Hz, Plectron, Quick-
Call I (2+2), and 5/6 Tone Sequential.
Paging formats are limited to Motorola
Two-Tone, GE Two-Tone, DTMF, and
alert tones.
I
Instant Call Paging enabled. This
allows frequently used pages or
sequences of pages to be initiated and
automatically steered to the correct
channel with a single key press.
Instant Call Paging disabled. All pages
are entered manually.
If an option code is not displayed, that option is set to the default condition.
Note
The data rate for the Model 4018 Console, Model 4118 Console,
and Model 4217B Audio Panel is set in the Option Code and must
be configured in the EPROM before shipment.
Содержание 4000 Series
Страница 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Страница 6: ...6 025 9533Y...
Страница 28: ...Introduction 28 025 9533Y...
Страница 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Страница 110: ...Common Control Equipment Installation 110 025 9533Y...
Страница 172: ...Console Installation 172 025 9533Y...
Страница 192: ...Audio Level Adjustments 192 025 9533Y...
Страница 230: ...Accessory Installation 230 025 9533Y...
Страница 236: ...Console ANI Programming 236 025 9533Y...
Страница 339: ...339 RSMP Operation Figure 99 Main Screen...
Страница 350: ...Radio System Management Program 350 025 9533Y...
Страница 362: ...Appendix B Troubleshooting 362 025 9533Y...
Страница 417: ...417 Index wiring accessories 164 wall jack 86 wiring diagram for M4219 244 X XMT button labels 332 XP settings 247...
Страница 418: ...Index 418 025 9533Y...