217
Using CPSW
If there are existing cables already connected to any of these ports, you must
temporarily remove them while programming. Before removing these existing
cables, ensure they are labeled so they can be returned to the proper ports.
1. There is an unlabeled switch on the bottom of the Model 4010 used to switch the
console between RUN and PROGRAM modes. Move the switch to the program
position, which is towards the gooseneck MIC and away from the DATA IN,
DATA OUT, and COMB jacks. (On the 4010R, this switch is on the back and the
positions are labeled.)
The console display shows “PROGRAM”.
2. Click
Communication, Send config to position, Send config to position x
(where x is the number of the position you are connected to).
CPSW prevents sending a configuration to a position if there are no configuration
settings for that position. If the position number you need is “greyed out”, you
must first configure that position (see
3. Click
OK
to begin sending the configuration settings.
The mouse cursor switches to an hourglass while CPSW is sending data. Although
CPSW displays “Configuration data sent to position x” when all data is sent,
CPSW is sending the data to the serial port blindly. In other words, the CPSW
application is not aware if a console is actually connected or not or if the console
successfully received the configuration information.
4. The download is successfully completed if the console displays “** DONE **”. If
the console does not display “** DONE **”, then some troubleshooting is
required:
a. If the console display shows “PROGRAM” after CPSW is done sending, then
there was a communication break between the PC and console, such as a serial
cable not connected or a wrong COM port configured in CPSW.
b. If the console continues to display “DnLoading CPS” long after CPSW is done
sending, then the serial transfer was interrupted after it started. The cable may
have been disconnected or the baud rate changed in the middle of the
download (Windows XP will occasionally change the baud rate by itself).
There is no timeout function on the console, so it will continue to display
"DnLoading CPS" until reset or switched back to 'Run' mode.
Note
The USB-to-serial port adapter provided by Zetron (P/N 802-0516)
is tested and the recommended adapter for this application. Many
third party USB-to-serial port adapters are inconsistent with their
serial port implementation and do not reliably communicate with
Zetron equipment.
Содержание 4000 Series
Страница 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Страница 6: ...6 025 9533Y...
Страница 28: ...Introduction 28 025 9533Y...
Страница 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Страница 110: ...Common Control Equipment Installation 110 025 9533Y...
Страница 172: ...Console Installation 172 025 9533Y...
Страница 192: ...Audio Level Adjustments 192 025 9533Y...
Страница 230: ...Accessory Installation 230 025 9533Y...
Страница 236: ...Console ANI Programming 236 025 9533Y...
Страница 339: ...339 RSMP Operation Figure 99 Main Screen...
Страница 350: ...Radio System Management Program 350 025 9533Y...
Страница 362: ...Appendix B Troubleshooting 362 025 9533Y...
Страница 417: ...417 Index wiring accessories 164 wall jack 86 wiring diagram for M4219 244 X XMT button labels 332 XP settings 247...
Страница 418: ...Index 418 025 9533Y...