Console Installation
156
This chapter describes the physical placement, configuring, and wiring of the dispatch
console and accessory control panels. This chapter covers the Desktop Console Model
4018, the Rackmount Console Model 4118 (with expansion panel 4115B), and the Model
4217B Audio Panel. For installation information for the video display console with
IntegratorRD, please refer to
IntegratorRD Workstation Installation
Physical Placement, Desktop
When placing a Model 4018 desktop console, consider the amount of desktop space
required not only for the desktop units, but also for a writing surface and the placement of
accessory items (external speakers, microphones, foot switches, and headset jackboxes).
Another consideration is the proximity of a power outlet and the CCE wiring jacks. Unless
special provisions have been made, units should not be placed more than 2000 wiring feet
from the CCE. Short Haul Modems (P/N 950-9222) are required beyond 2000 feet and up
to 1 mile. The VoIP Console Gateway (P/N 905-0265) is required for distances longer than
a mile.
Labelling
The buttons on the console usually come from the factory with key tops engraved to match
the function programmed by Zetron. If key function changes, additional engraved and
clear key tops are provided. To remove a key top, pull it directly away from the front
panel. The white plastic plunger may stay with the key top or the switch housing.
Console Access
The connectors and option wiring for the Model 4018 console are located on the back
panel of the console. The back panel also includes the status lights, which must be
monitored during system checkout and troubleshooting. To gain access to make
adjustments, open the top of the console in a “clam shell” fashion. This requires seventeen
inches of vertical space. A service loop on the wiring may be necessary for ease of access.
Note
In systems where there are both IntegratorRD video displays and
button-based consoles, the video position must be installed with
the first CIC.
Содержание 4000 Series
Страница 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Страница 6: ...6 025 9533Y...
Страница 28: ...Introduction 28 025 9533Y...
Страница 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Страница 110: ...Common Control Equipment Installation 110 025 9533Y...
Страница 172: ...Console Installation 172 025 9533Y...
Страница 192: ...Audio Level Adjustments 192 025 9533Y...
Страница 230: ...Accessory Installation 230 025 9533Y...
Страница 236: ...Console ANI Programming 236 025 9533Y...
Страница 339: ...339 RSMP Operation Figure 99 Main Screen...
Страница 350: ...Radio System Management Program 350 025 9533Y...
Страница 362: ...Appendix B Troubleshooting 362 025 9533Y...
Страница 417: ...417 Index wiring accessories 164 wall jack 86 wiring diagram for M4219 244 X XMT button labels 332 XP settings 247...
Страница 418: ...Index 418 025 9533Y...