3. Locate the Data-to-CCE cable. Connect the 9-pin D-connector end of the cable to
the socket marked
CCE
on the dual RS-422 card in the console position PC.
4. Route the Data-to-CCE cable to the Common Control Equipment cabinet. Connect
the 6-pin modular plug end of cable to the console
DATA
connection there.
5. Locate the Voice-to-CCE cable. Connect one end to the connector on the rear panel
of the Model 4219 labeled
VOICE
. Route the other end to the Common Control
Equipment cabinet and plug it into the console
VOICE
connection there.
6. Locate the Audio Y-cable (709-0123) and plug it into the jack on the rear of the
Model 4219 marked
AMPLIFIED SPEAKERS
. Connect the other end to the left
and right amplified speakers as appropriate.
7. Locate the two Power Y-cables (709-0159 and 709-7938). One of the plugs has a
threaded locking ring. Insert that plug into the connector on the rear of the Model
4219 labeled
12V PWR
and turn the locking ring tight.
8. Install the strain relief provided with the Model 4219 to prevent the cable from
becoming disconnected. See
Model 4219 Power Connection Strain Relief
158 for instructions on how to do this.
9. Plug the second Power Y-cable into either one of the sockets on the Y-cable
connected to the Model 4219. Plug the 12V power supply that came with the
Model 4219 into the remaining socket on that Y-cable.
10. Connect the two free sockets on the second Power Y-cable to the power leads
going to the external amplified speakers.
11. (Touch-screen) If an installer-supplied touch screen monitor is used, connect the
touch screen cable connector marked
To Touch screen
to the touch screen
monitor. Connect the opposite end, marked
To Touch screen Controller
to one of
the USB
connectors on the back of the PC.
12. Connect the 15-pin CRT video cable to the video connector on the PC.
13. Connect the mouse or trackball cable to the PC.
14. Connect the PC keyboard to the PC.
15. Connect the AC power cords for the PC and the monitor.
shows the cabling for an IntegratorRD workstation. The PC port locations that
are shown are for example only; they may not match your PC’s configuration.
Note
Содержание 4000 Series
Страница 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Страница 6: ...6 025 9533Y...
Страница 28: ...Introduction 28 025 9533Y...
Страница 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Страница 110: ...Common Control Equipment Installation 110 025 9533Y...
Страница 172: ...Console Installation 172 025 9533Y...
Страница 192: ...Audio Level Adjustments 192 025 9533Y...
Страница 230: ...Accessory Installation 230 025 9533Y...
Страница 236: ...Console ANI Programming 236 025 9533Y...
Страница 339: ...339 RSMP Operation Figure 99 Main Screen...
Страница 350: ...Radio System Management Program 350 025 9533Y...
Страница 362: ...Appendix B Troubleshooting 362 025 9533Y...
Страница 417: ...417 Index wiring accessories 164 wall jack 86 wiring diagram for M4219 244 X XMT button labels 332 XP settings 247...
Страница 418: ...Index 418 025 9533Y...