107
Modem and Service Port Operation
Figure 26: Example History File
The I and X options toggle whether or not the card configuration reports are included in
the display of the history log. If they are excluded, the history log will only show system
changes and errors. After typing
I
or
X
to change these options, you will exit the history
log menu. Press
H
to re-enter the menu.
23 Sep 1998
08:49:00.42 ( 112) This is STC1, in control of the system
08:49:00.00 ( 113) This is STC1, NOT in control of the system
08:48:59.32 ( 103) Clock source = Console
22 Sept 1998
00:00:13.30 ( 94) Console 2 CIC-OC console retry timeout error
00:00:13.28 ( 124) Console cardcage ERROR turned on
00:00:12.45 ( 112) This is STC1, in control of the system
00:00:12.03 ( 113) This is STC1, NOT in control of the system
00:00:09.82 ( 125) Console cardcage ERROR turned off
10:31:14.53 ( 91) Cage 2, slot 8 Inactive
10:31:17.90 ( 93) Channel 15 card reset
10:31:24.07 ( 90) Cage 2, slot 1 Active
10:31:24.07 ( 90) Cage 2, slot 8 Active
10:31:24.08 ( 90) Cage 2, slot 9 Active
10:31:24.08 ( 90) Cage 2, slot 11 Active
10:31:24.09 ( 90) Cage 2, slot 15 Active
10:31:24.09 ( 90) Cage 3, slot 7 Active
10:31:24.10 ( 90) Cage 1, slot 3 Active
10:31:24.10 ( 90) Cage 1, slot 4 Active
10:31:24.11 ( 90) Cage 1, slot 10 Active
10:31:24.11 ( 90) Cage 1, slot 11 Active
10:31:24.12 ( 90) Cage 1, slot 12 Active
10:31:24.12 ( 90) Cage 1, slot 18 Active
10:31:26.11 ( 96) M4048 Card Configuration Report follows:
Cage/Slot Card description Ver BTI Card-unique Crossmute Duplex
--------- --------------------- --- --- ------------ --------- ------
1 / 1 System traffic 1
1 / 2 System traffic 1
1 / 3 Console 1 Interface 1
1 / 4 Console 2 Interface 1
1 / 10 Console 8 Interface 1
1 / 11 Console 9 Interface 1
1 / 12 Console 10 Interface 1
1 / Patch card 1 24 patches
2 / 1 Channel 1 Local type 5 Off Disabled Half
2 / 1 Channel 2 Local type 5 Off Disabled Half
2 / 8 Channel 15 Tone type 5 Off 120ms G.T. Disabled Full
2 / 8 Channel 16 Tone type 5 Off 120ms G.T. Disabled Full
2 / 9 Channel 17 Tone type 5 Off 120ms G.T. Disabled Full
2 / 9 Channel 18 Tone type 5 Off 120ms G.T. Disabled Full
2 / 11 Channel 21 MAP27 10 Off Disabled Full
2 / 11 Channel 22 MAP27 10 Off Disabled Full
2 / 15 Channel 29 Tone type 10 Off 120ms G.T. Disabled Half
2 / 15 Channel 30 Tone type 10 Off 600ms G.T. Enabled Half
Aux-I/O addr 5 2
Touch <enter> for more data, or q + <enter> to quit.
Содержание 4000 Series
Страница 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Страница 6: ...6 025 9533Y...
Страница 28: ...Introduction 28 025 9533Y...
Страница 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Страница 110: ...Common Control Equipment Installation 110 025 9533Y...
Страница 172: ...Console Installation 172 025 9533Y...
Страница 192: ...Audio Level Adjustments 192 025 9533Y...
Страница 230: ...Accessory Installation 230 025 9533Y...
Страница 236: ...Console ANI Programming 236 025 9533Y...
Страница 339: ...339 RSMP Operation Figure 99 Main Screen...
Страница 350: ...Radio System Management Program 350 025 9533Y...
Страница 362: ...Appendix B Troubleshooting 362 025 9533Y...
Страница 417: ...417 Index wiring accessories 164 wall jack 86 wiring diagram for M4219 244 X XMT button labels 332 XP settings 247...
Страница 418: ...Index 418 025 9533Y...