387
Description of Key Functions and Parameters
If a primary or secondary ANI address is programmed, and your radios support RSC, and
Spare Outputs 7 and 8 are not programmed, then Spare Outputs 7 and 8 will function as
follows:
• Spare Output 7: ON when ANI is displayed on the console display, OFF otherwise
• Spare Output 8: Produces a 500 ms pulse when an ANI is decoded by the console
Auxiliary Input
By assigning an input to this key, the associated LEDs will reflect the state of the input.
Pick the desired inputs by entering the input numbers. The input must have been
previously defined using the System Configuration menu. Then select the desired LED
behavior.
Auxiliary Output Interlocked
Several outputs may be “interlocked” such that only one output can be active at any given
moment. That is, when one output goes active, all others will be inactive. Up to 32
interlock groups may be defined with any number of outputs per group.
Enter the desired output number up to 240. The output number will be accepted if it has
been previously defined using the System Configuration menu.
Type an interlock group number 1 - 32. If the interlock group has been already used, this
input will be added to it. If not, a new interlock group will be created.
Auxiliary Output Toggle
The chosen output will toggle with this key. That is, press the key once and the output will
be activated; press again and the output will deactivate.
Auxiliary Output Momentary
As long as this key is pressed, the output will be active; when released, the output will be
inactive.
Spare Output
Spare Output Latching
The eight spare outputs are located on pin block P1 of the Models 4118 and 4116B and on
P7 of the Model 4018 console. When an output is ON, its voltage is greater than +3.5 volts
DC relative to ground. When the output is OFF, its state is less than +0.5 volts.
If Spare outputs 7 and 8 are not reprogrammed, Spare Output 7 will be ON whenever an
ANI is displayed on the console and Spare Output 8 will produce a 500 ms pulse every
time an ANI is decoded by the console.
The assigned spare output will toggle on and off with each press of the spare output
latching key. The red LED will toggle to show the state of the output.
Содержание 4000 Series
Страница 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Страница 6: ...6 025 9533Y...
Страница 28: ...Introduction 28 025 9533Y...
Страница 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Страница 110: ...Common Control Equipment Installation 110 025 9533Y...
Страница 172: ...Console Installation 172 025 9533Y...
Страница 192: ...Audio Level Adjustments 192 025 9533Y...
Страница 230: ...Accessory Installation 230 025 9533Y...
Страница 236: ...Console ANI Programming 236 025 9533Y...
Страница 339: ...339 RSMP Operation Figure 99 Main Screen...
Страница 350: ...Radio System Management Program 350 025 9533Y...
Страница 362: ...Appendix B Troubleshooting 362 025 9533Y...
Страница 417: ...417 Index wiring accessories 164 wall jack 86 wiring diagram for M4219 244 X XMT button labels 332 XP settings 247...
Страница 418: ...Index 418 025 9533Y...