2 Bytes
I
C - - W -
DPT_Value_Temp
-273.00 -
670760.00
-
-
[Disp] [x2] (Climate) Temperature
Object value is shown (-99ºC to
199ºC)
2 Bytes
I
C - - W -
9.xxx
-671088.64 -
670760.96
-
-
[Disp] [x2] Icon - Range (float)
Selected icon shown on new range
of values reception
2 Bytes
I
C - - W -
9.xxx
-671088.64 -
670760.96
-
-
[Disp] [x2] Text - Range (float)
Selected text shown on new range
of values reception
91, 107, 123,
139
4 Bytes
I
C - - W -
DPT_Value_4_Ucoun
t
0 -
4294967295
-
-
[Disp] [x2] Number - Counter (4 bytes
unsigned)
Object numeric value is shown
4 Bytes
I
C - - W -
DPT_Value_4_Ucoun
t
0 -
4294967295
-
-
[Disp] [x2] Level - Counter (4 bytes
unsigned)
Level representing obect value is
shown
92, 108, 124,
140
14 Bytes
I
C - - W -
DPT_String_8859_1
-
-
-
[Disp] [x2] Text from object
Received text is shown
93, 109, 125,
141
1 Bit
I
C - - W -
DPT_Heat_Cool
0/1
-
-
[Disp] [x2] (Climate) On/Off – Mode
0 = Cool; 1 = Heat. (Mode icon is
shown when On/Off = 1, and
Status = 0)
94, 110, 126,
142
1 Bit
I
C - - W -
DPT_Switch
0/1
-
-
[Disp] [x2] (Climate) On/Off - Status
0 = Halted; 1 = Running. (Status
icon is shown when On/Off = 1,
and Status = 1)
143
1 Byte
I
C - - W -
DPT_SceneControl
0-63; 128-191
-
-
[Thermostat] Scene Input
Scene Value
144, 145
2 Bytes
I
C - - W -
DPT_Value_Temp
-273.00 -
670760.00
25.0
-
[T1] Temperature Source X
External Sensor Temperature
146
2 Bytes
O
C T R - -
DPT_Value_Temp
-273.00 -
670760.00
-
-
[T1] Effective Temperature
Effective Control Temperature
147
1 Byte
I
C - - W -
DPT_HVACMode
1=Comfort
2=Standbyby
3=Economy
4=Building
Protection
-
√
-
[T1] Special Mode
1-byte HVAC Mode
148
1 Bit
I
C - - W -
DPT_Trigger
0/1
-
√
-
[T1] Special Mode: comfort
0 = Nothing; 1 = Trigger
1 Bit
I
C - - W -
DPT_Switch
0/1
-
√
-
[T1] Special Mode: comfort
0 = Off; 1 = On
149
1 Bit
I
C - - W -
DPT_Trigger
0/1
-
√
-
[T1] Special Mode: standby
0 = Nothing; 1 = Trigger
1 Bit
I
C - - W -
DPT_Switch
0/1
-
√
-
[T1] Special Mode: standby
0 = Off; 1 = On
150
1 Bit
I
C - - W -
DPT_Trigger
0/1
1
√
-
[T1] Special Mode: economy
0 = Nothing; 1 = Trigger
1 Bit
I
C - - W -
DPT_Switch
0/1
1
√
-
[T1] Special Mode: economy
0 = Off; 1 = On
151
1 Bit
I
C - - W -
DPT_Trigger
0/1
-
√
-
[T1] Special Mode: protection
0 = Nothing; 1 = Trigger
1 Bit
I
C - - W -
DPT_Switch
0/1
-
√
-
[T1] Special Mode: protection
0 = Off; 1 = On
152
1 Bit
I
C - - W -
DPT_Window_Door
0/1
-
-
[T1] Window Status (input)
0 = Closed; 1 = Open
153
1 Bit
I
C - - W -
DPT_Trigger
0/1
-
-
[T1] Comfort Prolongation
0 = Nothing; 1 = Timed Comfort
154
1 Byte
O
C T R - -
DPT_HVACMode
1=Comfort
2=Standbyby
3=Economy
4=Building
Protection
3
W
√
-
W
[T1] Special Mode Status
1-byte HVAC Mode
155
2 Bytes
I
C - - W -
DPT_Value_Temp
-273.00 -
670760.00
-
-
[T1] Setpoint
Thermostat Setpoint Input
2 Bytes
I
C - - W -
DPT_Value_Temp
-273.00 -
670760.00
-
-
[T1] Basic Setpoint
Reference Setpoint
156
1 Bit
I
C - - W -
DPT_Step
0/1
-
-
[T1] Setpoint Step
0 = -0.5ºC; 1 = +0.5ºC
157
2 Bytes
I
C - - W -
DPT_Value_Tempd
-670760.00 -
-
-
[T1] Setpoint Offset
Float Offset Value