TMD-Display One
Technical Support:
http://zennioenglish.zendesk.com
56
Hold & Release
”) when the user touches the button. The options are “Send
0” and “Send 1” (default).
Action on Release
: sets the value to be sent to the bus (again, through
“
[Btn] [Xn] Hold & Release
”) when the user stops touching the button. The
options are “Send 0” (default) and “Send 1”.
LED illumination control
: analogous to the homonymous parameter for the
“Disabled” and “Binary” functions (see above). The options in this case are
“Regular” and “Dedicated object”.
Two Objects (Short Press / Long Press)
Figure 45
Individual Button – Two Objects (short press / long press).
Long Press Threshold Time
: sets the minimum time the user should hold
the button in order to consider it a long press. The available range is 5 to 50
tenths of a second, being 5 tenths the default value.
Action on Short press
: sets the value to be sent to the bus (through “
[Btn]
[Xn] Two switches - Short press
”) when the user short-presses the button.
The options are “Send 0”, “Send 1”, “Toggle 0/1” and “Send 1-byte value”. In
case of selecting the latter, an additional parameter (“
Value
”) will be
displayed to enter the desired one-byte value (0 - 255).
Action on Long press
: sets the value to be sent to the bus (through “
[Btn]
[Xn] Two switches - Long press
”) when the user long-presses the button.
The options are the same as for the short press.