A2-6
IM 34M06H62-02E
3rd Edition : Jul.16, 2015-00
Table A2.4 Instrument Range and Accuracy (for low resolution operation with SW1-1 set to ON) 4/4
Input
Categor
y
Input Type
*1
Instrument Range
Input Type Selector Switch
*3
Software
Setting
Accuracy
*4
Resolution
*2
SW1-3 SW1-4 SW5
Software setting
ON
OFF
0
Instrument ranges may be specified by
software using one of the following codes.
Thermoco
uple
K
*5
-328 to 2498
F
ON OFF
1 33
($21)
2
F
*5
1
F
*5
-328 to 1832
F
2 34
($22)
2
F
*5
1
F
*5
-328 to 932
F
3 35
($23)
2
F 1
F
J
-328 to 2192
F
4 36
($24)
2
F 1
F
-328 to 932
F
5 37
($25)
2
F 1
F
T
-454 to 752
F
6 38
($26)
2
F
*6
1
F
B
*7
32 to 2912
F
7 39
($27)
2
F
*7
1
F
*7
S
*8
32 to 2912
F
8 40
($28)
2
F
*8
1
F
R
*8
32 to 2912
F
9 41
($29)
2
F
*8
1
F
N
-328 to 2372
F
A 42
($2A)
2
F
*9
1
F
E
-454 to 1832
F
B 43
($2B)
2
F
*10
1
F
*10
L
-328 to 1652
F
C 44
($2C)
2
F 1
F
U
-328 to 752
F
D 45
($2D)
2
F 1
F
W
*11
32 to 2912
F
E 46
($2E)
2
F 1
F
Platinel 2
32 to 2534
F
F 47
($2F)
2
F 1
F
RT
D
JPt100
-328 to 932
F
ON ON
0 48
($30)
2
F 1
F
-328 to 392
F
1 49
($31)
2
F 1
F
32 to 572
F
2 50
($32)
2
F 1
F
32 to 302
F
3 51
($33)
2
F 1
F
Pt100
-328 to 1562
F
4 52
($34)
2
F 1
F
-328 to 932
F
5 53
($35)
2
F 1
F
-328 to 392
F
6 54
($36)
2
F 1
F
32 to 572
F
7 55
($37)
2
F 1
F
32 to 302
F
8 56
($38)
2
F 1
F
*1:
Applicable standard is JIS/IEC/DIN (ITS-90) for thermocouples and RTD.
*2:
For thermocouples K, B, S, R, and W, input ranges may be set wider than their instrument range (see the notes below). Furthermore, the
actual range for an acceptable input is the input range
5%.
*3:
When you turn on the power after changing the hardware switch settings, data stored in the EEPROM is initialized to follow the switch
settings.
*4:
This accuracy applies if the ambient temperature is 77
F
9
F and the input value is within the instrument range. If the input type is
thermocouple and reference junction compensation is used, you should also take into consideration the accuracy of the reference
junction compensation.
*5:
For K-type thermocouples, the upper and lower input range limits may be set from -454 to 2498
F. The accuracy and resolution depend
on measured temperatures as follows:
-454
to
328
F: Neither accuracy nor resolution is guaranteed.
*6:
For T-type thermocouples, the accuracy and resolution depend on measured temperatures as follows:
-454
to
-328
F:
7
F accuracy, 1
F resolution
*7:
For B-type thermocouples, the upper and lower input range limits may be set from 32 to 3272
F. The accuracy and resolution depend on
measured temperatures as follows:
32 to 572
F: Neither accuracy nor resolution is guaranteed.
572 to 1652
F:
5
F accuracy, 1
F resolution
*8:
For S-type and R-type thermocouples, the upper and lower input range limits may be set from 32 to 3092
F. The accuracy and
resolution depend on measured temperatures as follows:
32 to 392
F:
3
F accuracy, 1
F resolution
*9:
For N-type thermocouples, the accuracy and resolution depend on measured temperatures as follows:
-328
to
32
F:
4
F accuracy, 1
F resolution
*10: For E-type thermocouples, the detailed accuracy and resolution are as follows:
-454
to
328
F:
12
F accuracy, 4
F resolution
-328
to
148
F:
3
F accuracy, 1
F resolution
*11: For W-type thermocouples, the upper and lower input range limits may be set from 32 to 4172
F.
Содержание F3CU04-0S
Страница 2: ...Blank Page...
Страница 18: ...Blank Page...
Страница 32: ...Blank Page...
Страница 34: ...Blank Page...
Страница 50: ...Blank Page...
Страница 90: ...Blank Page...
Страница 97: ...B3 7 IM 34M06H62 02E 2nd Edition June 2008 00 Figure B3 2 Sample Program for Setting Controller Parameters 2 2...
Страница 100: ...B3 10 IM 34M06H62 02E 2nd Edition June 2008 00 Figure B3 3 Sample Program for Setting I O Parameters 2 3...
Страница 101: ...B3 11 IM 34M06H62 02E 2nd Edition June 2008 00 Figure B3 3 Sample Program for Setting I O Parameters 3 3...
Страница 110: ...B4 2 IM 34M06H62 02E 2nd Edition June 2008 00 Figure B4 1 Sample Program Component for Setting Setup Parameters 2 5...
Страница 111: ...B4 3 IM 34M06H62 02E 2nd Edition June 2008 00 Figure B4 1 Sample Program Component for Setting Setup Parameters 3 5...
Страница 112: ...B4 4 IM 34M06H62 02E 2nd Edition June 2008 00 Figure B4 1 Sample Program Component for Setting Setup Parameters 4 5...
Страница 113: ...B4 5 IM 34M06H62 02E 2nd Edition June 2008 00 Figure B4 1 Sample Program Component for Setting Setup Parameters 5 5...
Страница 118: ...Blank Page...
Страница 130: ...Blank Page...
Страница 204: ...Blank Page...
Страница 215: ...C8 1 IM 34M06H62 02E 2nd Edition June 2008 00 C8 Alarm Function This chapter describes the alarm function of the module...
Страница 222: ...Blank Page...
Страница 224: ...Blank Page...
Страница 228: ...Blank Page...
Страница 230: ...Blank Page...
Страница 232: ...Blank Page...
Страница 234: ...Blank Page...
Страница 240: ...Blank Page...
Страница 242: ...Blank Page...
Страница 254: ...Blank Page...
Страница 258: ...Blank Page...
Страница 260: ...Blank Page...