![YASKAWA Z1000U Series Скачать руководство пользователя страница 278](http://html2.mh-extra.com/html/yaskawa/z1000u-series/z1000u-series_programming-manual_3226538278.webp)
No.
Name
Unit
Default Settings
E5-06
Motor d-Axis Inductance (Ld) (for
PM Motors)
mH
3.99
2.97
2.44
1.87
1.49
1.41
1.22
E5-07
Motor q-Axis Inductance (Lq) (for
PM Motors)
mH
5.39
3.90
3.23
2.46
2.08
1.88
1.51
E5-09
Motor Induction Voltage Constant
1 (Ke) (for PM Motors)
mVs
/rad
853.8
829.6
835.6
833.4
848.6
889.1
915.0
E5-24
Motor Induction Voltage Constant
2 (Ke) (for PM Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
n8-49
d-Axis Current for High
Efficiency Control (for PM
Motors) (OLV/PM)
%
-16.0
-15.7
-15.7
-14.7
-16.5
-14.1
-10.4
A.19 Parameters Changed by Motor Code Selection (for PM Motors)
278