![YASKAWA Z1000U Series Скачать руководство пользователя страница 272](http://html2.mh-extra.com/html/yaskawa/z1000u-series/z1000u-series_programming-manual_3226538272.webp)
No.
Name
Unit
Default Settings
n8-49
d-Axis Current for High
Efficiency Control (for PM
Motors) (OLV/PM)
%
-7.5
-8.5
-9.8
-8.2
-9.1
-13.1
-9.2
-12.4
Table A.32 400 V, 1750 r/min Type Yaskawa SST4 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for
PM Motors)
-
223E
223F
2240
2242
2243
2244
2245
2246
Voltage Class
V
400
400
400
400
400
400
400
400
Rated Power
kW
15
18
22
30
37
45
55
75
Rated Speed
r/min
1750
1750
1750
1750
1750
1750
1750
1750
E5-02
Motor Rated Power (for PM
Motors)
kW
15
18.50
22.00
30.00
37.00
45.00
55.00
75.00
E5-03
Motor Rated Current (for PM
Motors)
A
26.4
34.2
38.8
52.2
65.4
77.6
99.3
130.2
E5-04
Number of Motor Poles (for
PM Motors)
–
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1)
(for PM Motors)
Ω
0.275
0.196
0.160
0.120
0.077
0.052
0.036
0.023
E5-06
Motor d-Axis Inductance
(Ld) (for PM Motors)
mH
9.99
7.92
6.82
5.24
3.57
2.98
1.59
1.59
E5-07
Motor q-Axis Inductance
(Lq) (for PM Motors)
mH
12.37
9.64
8.51
6.44
4.65
3.75
2.78
1.97
E5-09
Motor Induction Voltage
Constant 1 (Ke) (for PM
Motors)
mVs
/rad
505.3
489.2
509.5
566.2
531.6
530.6
515.2
515.2
E5-24
Motor Induction Voltage
Constant 2 (Ke) (for PM
Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-05
Maximum Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-09
Minimum Output Frequency
Hz
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
n8-49
d-Axis Current for High
Efficiency Control (for PM
Motors) (OLV/PM)
%
-15.1
-14.3
-15.3
-11.3
-14.5
-13.2
-22.6
-11.9
Table A.33 400 V, 1750 r/min Type Yaskawa SST4 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for
PM Motors)
-
2247
2248
2249
224A
224C
224D
224E
2302
Voltage Class
V
400
400
400
400
400
400
400
200
Rated Power
kW
90.00
110
132
160
200
220
300
0.4
Rated Speed
r/min
1750
1750
1750
1750
1750
1750
1750
1450
E5-02
Motor Rated Power (for PM
Motors)
kW
90.00
110.00
132.00
160.00
200.00
250.00
300.00
0.4
E5-03
Motor Rated Current (for PM
Motors)
A
153.1
184.4
229.2
269.8
346.9
421.9
520.8
1.77
E5-04
Number of Motor Poles (for
PM Motors)
–
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1)
(for PM Motors)
Ω
0.019
0.017
0.012
0.008
0.005
0.004
0.002
3.154
E5-06
Motor d-Axis Inductance
(Ld) (for PM Motors)
mH
1.51
1.43
1.13
0.96
0.65
0.67
0.40
28.46
E5-07
Motor q-Axis Inductance
(Lq) (for PM Motors)
mH
1.76
1.92
1.54
1.26
0.88
0.74
0.52
39.29
E5-09
Motor Induction Voltage
Constant 1 (Ke) (for PM
Motors)
mVs
/rad
538.3
590.9
548.2
603.9
556.8
593.1
495.4
268.8
E5-24
Motor Induction Voltage
Constant 2 (Ke) (for PM
Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
A.19 Parameters Changed by Motor Code Selection (for PM Motors)
272