![YASKAWA Z1000U Series Скачать руководство пользователя страница 262](http://html2.mh-extra.com/html/yaskawa/z1000u-series/z1000u-series_programming-manual_3226538262.webp)
No.
Name
Unit
Default Settings
–
Drive Model
–
4
o
0180
4
o
0216
4
o
0240
4
o
0302
4
o
0361
4
o
0414
o2-04
Drive Model Selection
Hex.
A5
A6
A7
A8
A9
AA
E2-11
Motor Rated Output
kW (HP)
110 (150)
132 (175)
150 (200)
185 (250)
220 (300)
260 (350)
E2-01
Motor Rated Current
A
156
190
223
270
310
370
E2-02
Motor Rated Slip
Hz
1.4
1.4
1.38
1.35
1.3
1.3
E2-03
Motor No-Load Current
A
40
49
58
70
81
96
E2-05
Motor Line-to-Line Resistance
Ω
0.056
0.046
0.035
0.029
0.025
0.02
E2-06
Motor Leakage Inductance
%
20
20
20
20
20
20
E2-10
Motor Iron Loss for Torque
Compensation
W
1760
2150
2350
2850
3200
3700
E5-01
Motor Code Selection (for PM
Motors)
Hex.
1246
1247
1248
1249
124A
FFFF
L2-02
Momentary Power Loss Ride-Thru
Time
s
1.5
1.7
1.7
1.8
1.9
2
L2-03
Momentary Power Loss Minimum
Baseblock Time
s
1
1
1
1
1
1
L2-04
Momentary Power Loss Voltage
Recovery Time
s
300
300
300
300
300
300
L8-02
Overheat Alarm Level
°C
130
130
130
130
130
130
L8-35
Installation Method Selection
–
0
0
0
0
0
0
L8-38
Carrier Frequency Reduction
Selection
–
1
1
1
1
1
1
n1-03
Hunting Prevention Time Constant
ms
30
30
30
30
30
100
Table A.13 400 V Class Drives Default Settings by Drive Model Selection
No.
Name
Unit
Default Settings
–
Drive Model
–
4
o
0361
4
o
0414
o2-04
Drive Model Selection
Hex.
A9
AA
E2-11 (E4-11)
Motor Rated Output
kW (HP)
220 (300)
260 (350)
b3-04
V/f Gain during Speed Search
%
60
60
b3-06
Output Current 1 during Speed Search
–
0.7
0.7
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
–
0.8
0.8
b8-03
Energy Saving Control Filter Time Constant
s
2.00
2.00
b8-04
Energy Saving Coefficient Value
–
30.57
27.13
C5-17 (C5-37)
Motor Inertia
kgm
2
3.60
4.10
C6-02
Carrier Frequency Selection
–
1
1
E2-01 (E4-01)
Motor Rated Current
A
310
370
E2-02 (E4-02)
Motor Rated Slip
Hz
1.3
1.3
E2-03 (E4-03)
Motor No-Load Current
A
81
96
E2-05 (E4-05)
Motor Line-to-Line Resistance
Ω
0.025
0.02
E2-06 (E4-06)
Motor Leakage Inductance
%
20
20
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
W
3200
3700
E5-01
Motor Code Selection (for PM Motors)
Hex.
124A
FFFF
L2-02
Momentary Power Loss Ride-Thru Time
s
1.9
2
L2-03
Momentary Power Loss Minimum Baseblock Time
s
1
1
L2-04
Momentary Power Loss Voltage Recovery Time
s
300
300
L2-21
Low Input Voltage Detection Level
V
300
300
L8-02
Overheat Alarm Level
°C
130
130
L8-35
Installation Method Selection
–
0
0
L8-38
Carrier Frequency Reduction Selection
–
1
1
n1-03
Hunting Prevention Time Constant
ms
30
100
n5-02
Motor Acceleration Time
s
0.864
0.91
A.18 Defaults by Drive Model
262
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual