Table A.28 400 V, 1150 r/min Type Yaskawa SSR1 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM
Motors)
−
1443
1444
1445
1446
1447
1448
Voltage Class
V
400
400
400
400
400
400
Rated Power
kW
37
45
55
75
90
110
Rated Speed
r/min
1150
1150
1150
1150
1150
1150
E5-02
Motor Rated Power (for PM
Motors)
kW
37.00
45.00
55.00
75.00
90.00
110.00
E5-03
Motor Rated Current (for PM
Motors)
A
64.8
76.6
92.0
127.1
150.5
185.4
E5-04
Number of Motor Poles (for PM
Motors)
−
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for
PM Motors)
Ω
0.093
0.063
0.051
0.033
0.027
0.015
E5-06
Motor d-Axis Inductance (Ld) (for
PM Motors)
mH
6.13
4.63
3.96
3.03
2.60
1.89
E5-07
Motor q-Axis Inductance (Lq) (for
PM Motors)
mH
9.10
6.15
5.00
5.14
3.28
2.33
E5-09
Motor Induction Voltage Constant
1 (Ke) (for PM Motors)
mVs
/rad
857.7
866.6
854.0
823.1
853.4
829.2
E5-24
Motor Induction Voltage Constant
2 (Ke) (for PM Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
u
Yaskawa SST4 Series IPM Motor (For Constant Torque)
Table A.29 200 V, 1750 r/min Type Yaskawa SST4 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM
Motors)
-
2202
2203
2205
2206
2208
220A
220B
220D
Voltage Class
V
200
200
200
200
200
200
200
200
Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
Rated Speed
r/min
1750
1750
1750
1750
1750
1750
1750
1750
E5-02
Motor Rated Power (for PM
Motors)
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
E5-03
Motor Rated Current (for PM
Motors)
A
1.77
3.54
6.56
8.96
14.79
20.94
29.58
41.1
E5-04
Number of Motor Poles (for PM
Motors)
–
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for
PM Motors)
Ω
2.247
1.132
0.774
0.479
0.242
0.275
0.161
0.111
E5-06
Motor d-Axis Inductance (Ld)
(for PM Motors)
mH
22.32
12.38
8.90
7.39
5.06
5.82
3.86
3.59
E5-07
Motor q-Axis Inductance (Lq)
(for PM Motors)
mH
32.50
15.72
11.96
9.63
6.42
6.74
4.66
4.32
E5-09
Motor Induction Voltage
Constant 1 (Ke) (for PM Motors)
mVs
/rad
215.2
203.9
219.3
230.6
235.1
251.7
235.7
252.0
E5-24
Motor Induction Voltage
Constant 2 (Ke) (for PM Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-05
Maximum Voltage
V
190.0
190.0
190.0
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-09
Minimum Output Frequency
Hz
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
n8-49
d-Axis Current for High
Efficiency Control (for PM
Motors) (OLV/PM)
%
-9.3
-6.4
-10.0
-9.9
-9.7
-8.4
-11.5
-13.1
A.19 Parameters Changed by Motor Code Selection (for PM Motors)
270