6.3 FT41 Specification
6.3.1 List of Servo Parameters
6-89
6
Parameter Lists
Pn475
2
Gravity Compensation-
Related Selections
0000h to
0001h
–
0000h
All
After
restart
Setup
*1
Pn476
2
Gravity Compensation
Torque
-1,000 to
1,000
0.1%
0
All
Immedi-
ately
Tuning
*1
Pn480
2
Speed Limit during
Force Control
0 to 10,000
1 mm/s
100
Linear
Immedi-
ately
Setup
*1
Pn481
2
Polarity Detection
Speed Loop Gain
10 to 20,000
0.1 Hz
400
Linear
Immedi-
ately
Tuning
–
Pn482
2
Polarity Detection
Speed Loop Integral
Time Constant
15 to 51,200 0.01 ms
3000
Linear
Immedi-
ately
Tuning
–
Pn483
2
Forward Force Limit
0 to 800
1%
*3
30
Linear
Immedi-
ately
Setup
*1
Pn484
2
Reverse Force Limit
0 to 800
1%
*3
30
Linear
Immedi-
ately
Setup
*1
Pn485
2
Polarity Detection Refer-
ence Speed
0 to 100
1 mm/s
20
Linear
Immedi-
ately
Tuning
–
Pn486
2
Polarity Detection Refer-
ence Acceleration/
Deceleration Time
0 to 100
1 ms
25
Linear
Immedi-
ately
Tuning
–
Pn487
2
Polarity Detection Con-
stant Speed Time
0 to 300
1 ms
0
Linear
Immedi-
ately
Tuning
–
Pn488
2
Polarity Detection Refer-
ence Waiting Time
50 to 500
1 ms
100
Linear
Immedi-
ately
Tuning
–
Pn48E
2
Polarity Detection
Range
1 to 65,535
1 mm
10
Linear
Immedi-
ately
Tuning
–
Pn490
2
Polarity Detection Load
Level
0 to 20,000
1%
100
Linear
Immedi-
ately
Tuning
–
Pn495
2
Polarity Detection Con-
firmation Force Refer-
ence
0 to 200
1%
100
Linear
Immedi-
ately
Tuning
–
Pn498
2
Polarity Detection Allow-
able Error Range
0 to 30
1 deg
10
Linear
Immedi-
ately
Tuning
–
Pn49F
2
Speed Ripple Compen-
sation Enable Speed
0 to 10,000
1 mm/s
0
Linear
Immedi-
ately
Tuning
*1
Pn4A0
2
Pressure Feedback
One-Parameter Gain
Level
1 to 65,535
–
1000
All
Immedi-
ately
Setup
Pn4A3
2
Reserved parameter (Do
not change.)
–
–
100
All
–
–
–
Pn4A7
2
Pressure Feedback
Control 2 Stability Gain
10 to 20,000
0.1 Hz
400
All
Immedi-
ately
Setup
Pn4A8
2
Pressure Feedback
Control 2 Stability Inte-
gral Time
15 to 51,200 0.01 ms
2000
All
Immedi-
ately
Setup
Pn4A9
2
Reserved parameter (Do
not change.)
–
–
400
All
–
–
–
Pn4AA
2
Reserved parameter (Do
not change.)
–
–
2000
All
–
–
–
Pn4AB
2
Reserved parameter (Do
not change.)
–
–
0
All
–
–
–
Pn4AC
2
Pressure Feedback
Moment of Inertia Ratio
0 to 20,000
1%
100
All
Immedi-
ately
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Gravity Compensation Selection
0
Disable gravity compensation.
1
Enable gravity compensation.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Содержание SGD7S-R70A20A023F40B