6.2 FT40 Specification
6.2.1 List of Servo Parameters
6-4
6.2
FT40 Specification
6.2.1
List of Servo Parameters
The following table lists the parameters.
Note: Do not change the following parameters from their default settings.
•
Reserved parameter
•
Parameters not given in this manual
•
Parameters that are not valid for the Servomotor that you are using, as given in the parameter table
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
Pn000
2
Basic Function Selec-
tions 0
0000h to
10B1h
–
0000h
All
After
restart
Setup
*1
Continued on next page.
n.
X
Rotation Direction Selection
Movement Direction Selection
0
Use CCW as the forward direction.
Use the direction in which the linear encoder counts up as the forward direc-
tion.
1
Use CW as the forward direction. (Reverse Rotation Mode)
Use the direction in which the linear encoder counts down as the forward
direction. (Reverse Movement Mode)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Rotary/Linear Servomotor Startup Selection When Encoder Is Not Connected
0
When an encoder is not connected, start as SERVOPACK for Rotary Servo-
motor.
1
When an encoder is not connected, start as SERVOPACK for Linear Servo-
motor.