6.3 FT41 Specification
6.3.1 List of Servo Parameters
6-71
6
Parameter Lists
Pn001
2
Application Function
Selections 1
0000h to
1142h
–
0000h
All
After
restart
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Motor Stopping Method for Servo OFF and Group 1 Alarms
0
Stop the motor by applying the dynamic brake.
1
Stop the motor by the applying dynamic brake and then release the dynamic
brake.
2
Coast the motor to a stop without the dynamic brake.
n.
X
Overtravel Stopping Method
0
Apply the dynamic brake or coast the motor to a stop (use the stopping
method set in Pn001 = n.
X).
1
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
torque and then servo-lock the motor.
2
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
torque and then let the motor coast.
3
Decelerate the motor to a stop using the deceleration time set in Pn30A and
then servo-lock the motor.
4
Decelerate the motor to a stop using the deceleration time set in Pn30A and
then let the motor coast.
n.
X
Main Circuit Power Supply AC/DC Input Selection
0
Input AC power as the main circuit power supply using the L1, L2, and L3 ter-
minals (do not use shared converter).
1
Input DC power as the main circuit power supply using the B1/
and
2
terminals or the B1 and
2 terminals (use an external converter or the
shared converter).
n.X
Reserved parameter (Do not change.)