6.3 FT41 Specification
6.3.1 List of Servo Parameters
6-77
6
Parameter Lists
Pn00C
2
Application Function
Selections C
0000h to
0131h
–
0000h
–
After
restart
Setup
*1
Pn00D
2
Application Function
Selections D
0000h to
1001h
–
0000h
All
After
restart
Setup
*1
Pn00F
2
Application Function
Selections F
0000h to
2011h
–
0000h
All
After
restart
Setup
*1
Pn021
2
Reserved parameter (Do
not change.)
–
–
0000h
All
–
–
–
Pn022
2
Reserved parameter (Do
not change.)
−
−
0000h
All
−
−
−
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Function Selection for Test without a Motor
Applicable
Motors
0
Disable tests without a motor.
All
1
Enable tests without a motor.
n.
X
Encoder Resolution for Tests without a Motor
Applicable
Motors
0
Use 13 bits.
Rotary
1
Use 20 bits.
2
Use 22 bits.
3
Use 24 bits.
n.
X
Encoder Type Selection for Tests without a Motor
Applicable
Motors
0
Use an incremental encoder.
All
1
Use an absolute encoder.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Overtravel Warning Detection Selection
0
Do not detect overtravel warnings.
1
Detect overtravel warnings.
n.
X
Preventative Maintenance Warning Selection
0
Do not detect preventative maintenance warnings.
1
Detect preventative maintenance warnings.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)