6.2 FT40 Specification
6.2.1 List of Servo Parameters
6-47
6
Parameter Lists
*1.
Refer to the following manual for details.
Σ
-7-Series
Σ
-7S SERVOPACK with MECHATROLINK-III Communications References Product Manual
(Manual No.: SIEP S800001 28)
*2.
Refer to the following manual for details.
Σ
-7-Series MECHATROLINK-III Communications Standard Servo Profile Command Manual
(Manual No.: SIEP S800001 31)
*3.
Set a percentage of the motor rated torque.
*4.
These parameters are for SERVOPACKs with a Safety Module. Refer to the following manual for details.
Σ
-V-Series/
Σ
-V-Series for Large-Capacity Models/
Σ
-7-Series User’s Manual Safety Module
(Manual No.: SIEP C720829 06)
*5.
Normally set this parameter to 0. If you use an External Regenerative Resistor, set the capacity (W) of the Exter-
nal Regenerative Resistor.
*6.
The upper limit is the maximum output capacity (W) of the SERVOPACK.
*7.
These parameters are for SERVOPACKs with the dynamic brake option. Refer to the following manual for
details.
Σ
-7-Series
Σ
-7S/
Σ
-7W SERVOPACK with Hardware Option Specifications Dynamic Brake Product Manual (Man-
ual No.: SIEP S800001 73)
*8.
This parameter is valid only when the MECHATROLINK-III standard servo profile is used.
*9.
The parameter setting is enabled after SENS_ON command execution is completed.
*10.
Change the setting when the reference is stopped (i.e., while DEN is set to 1). If you change the setting during
operation, the reference output will be affected.
*11.
The settings are updated only if the reference is stopped (i.e., only if DEN is set to 1).
*12.
Refer to the following manual for details.
Σ
-7-Series MECHATROLINK-II Communications Command Manual (Manual No.: SIEP S800001 30)
*13.
This parameter is valid only when the MECHATROLINK-II-compatible profile is used.
*14.
The setting of Pn842 is valid while Pn817 is set to 0.
*15.
The setting of Pn844 is valid while Pn818 is set to 0.
Pn884
2
Communications Con-
trols 2
0000h to
0001h
–
0000h
All
Immedi-
ately
Setup
*2
Pn88A
2
MECHATROLINK
Receive Error Counter
Monitor
(for maintenance, read
only)
0 to 65,535
–
0
All
–
Setup
–
Pn890 to
Pn8A6
4
Command Data Moni-
tor during Alarm/Warn-
ing
(for maintenance, read
only)
0h to
FFFFFFFFh
–
0h
All
–
Setup
*2
Pn8A8 to
Pn8BE
4
Response Data Monitor
during Alarm/Warning
(for maintenance, read
only)
0h to
FFFFFFFFh
–
0h
All
–
Setup
*2
Pn900
2
Number of Parameter
Banks
0 to 16
–
0
All
After
restart
Setup
*2
Pn901
2
Number of Parameter
Bank Members
0 to 15
–
0
All
After
restart
Setup
*2
Pn902 to
Pn910
2
Parameter Bank Mem-
ber Definition
0000h to
08FFh
–
0000h
All
After
restart
Setup
*2
Pn920 to
Pn95F
2
Parameter Bank Data
(Not saved in nonvolatile
memory.)
0000h to
FFFFh
–
0000h
All
Immedi-
ately
Setup
*2
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
M3
*8
n.
X
MECHATROLINK Communications Error Holding Brake Signal Setting
0
Maintain the status set by the BRK_ON or BRK_OFF command when a MECHA-
TROLINK communications error occurs.
1
Apply the holding brake when a MECHATROLINK communications error occurs.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)