6.3 FT41 Specification
6.3.1 List of Servo Parameters
6-97
6
Parameter Lists
Pn583
2
Brake Reference Out-
put Speed Level
0 to 10,000
1 mm/s
10
Linear
Immedi-
ately
Setup
*1
Pn584
2
Speed Limit Level at
Servo ON
0 to 10,000
1 mm/s
10000
Linear
Immedi-
ately
Setup
*1
Pn585
2
Program Jogging Move-
ment Speed
1 to 10,000
1 mm/s
50
Linear
Immedi-
ately
Setup
*1
Pn586
2
Motor Running Cooling
Ratio
0 to 100
1%/
Max.
speed
0
Linear
Immedi-
ately
Setup
–
Pn587
2
Polarity Detection Exe-
cution Selection for
Absolute Linear Encoder
0000h to
0001h
–
0000h
Linear
Immedi-
ately
Setup
*1
Pn600
2
Regenerative Resistor
Capacity
*5
Depends on
model.
*6
10 W
0
All
Immedi-
ately
Setup
*1
Pn601
2
Dynamic Brake Resis-
tor Allowable Energy
Consumption
0 to 65,535
10 J
0
All
After
restart
Setup
*7
Pn603
2
Regenerative Resis-
tance
0 to 65,535
10 m
Ω
0
All
Immedi-
ately
Setup
*1
Pn604
2
Dynamic Brake Resis-
tance
0 to 65,535
10 m
Ω
0
All
After
restart
Setup
*7
Pn61A
2
Reserved parameter (Do
not change.)
–
–
0000h
Linear
–
–
–
Pn61B
2
Reserved parameter (Do
not change.)
–
–
250
All
–
–
–
Pn61C
2
Reserved parameter (Do
not change.)
–
–
100
All
–
–
–
Pn61D
2
Reserved parameter (Do
not change.)
–
–
0
All
–
–
–
Pn621 to
Pn628
*4
–
Safety Module-Related
Parameters
–
–
–
All
–
–
–
Pn68E
4
Reserved parameter (Do
not change.)
0
Rotary
–
–
–
Pn690
2
Reserved parameter (Do
not change.)
0
Rotary
–
–
–
Pn692
2
Reserved parameter (Do
not change.)
0
Rotary
–
–
–
Pn694
2
Reserved parameter (Do
not change.)
0
Rotary
–
–
–
Pn696
2
Reserved parameter (Do
not change.)
0
Rotary
–
–
–
Pn698
2
Reserved parameter (Do
not change.)
0
Rotary
–
–
–
Pn69A
2
Reserved parameter (Do
not change.)
–
–
0
Rotary
–
–
–
Pn69C
2
Reserved parameter (Do
not change.)
–
–
0
Rotary
–
–
–
Pn69E
2
Reserved parameter (Do
not change.)
–
–
0
Rotary
–
–
–
Pn6A0
2
Reserved parameter (Do
not change.)
–
–
0
Rotary
–
–
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Polarity Detection Selection for Absolute Linear Encoder
0
Do not detect polarity.
1
Detect polarity.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Содержание SGD7S-R70A20A023F40B