5.2 FT41 Specification
5.2.5 List of Warnings
5-97
5
Maintenance
*
If using the commands for the MECHATROLINK-III standard servo profile, the warning will automatically be
cleared after the correct command is received.
Note: 1. A warning code is not output unless you set Pn001 to n.1
(Output both alarm codes and warning
codes).
2. Use Pn008 = n.
X
(Warning Detection Selection) to control warning detection.
However, the following warnings are not affected by the setting of Pn008 = n.
X
and other parameter
settings are required in addition to Pn008 = n.
X
.
A.9b0
Preventative Mainte-
nance Warning
One of the consumable parts has reached the end of its
service life.
Required.
Warning
Parameters That Must Be Set to Select Warning Detection
A.911
Pn310 = n.
X (Vibration Detection Selection)
A.923
–
(Not affected by the setting of Pn008 = n.
X
.)
A.930
Pn008 = n.
X (Low Battery Voltage Alarm/Warning Selection)
A.942
Pn423 = n.
X
(Speed Ripple Compensation Information Disagreement Warning
Detection Selection)
A.94A to A.960 and
A.97A to A.97b
Pn800=n.
X
(Warning Check Masks)
A.971
Pn008 = n.
X (Low Battery Voltage Alarm/Warning Selection)
(Not affected by the setting of Pn008 = n.
X
.)
A.9A0
Pn00D = n.X
(Overtravel Warning Detection Selection)
(Not affected by the setting of Pn008 = n.
X
.)
A.9b0
Pn00F = n.
X (Preventative Maintenance Warning Selection)
Continued from previous page.
Warning
Number
Warning Name
Meaning
Resetting
Содержание SGD7S-R70A20A023F40B