6.2 FT40 Specification
6.2.2 List of MECHATROLINK-III Common Parameters
6-53
6
Parameter Lists
8A
PnB14
4
Monitor Select for
SEL_MON2
0h to 9h
−
0h
All
Immedi-
ately
Command-r
e
la
te
d
parameters
8B
PnB16
4
Zero Point Detection
Range
0 to 250
1 reference
unit
10
All
Immedi-
ately
8C
PnB18
4
Forward Torque Limit
0 to 800
1%
100
All
Immedi-
ately
8D
PnB1A
4
Reverse Torque Limit
0 to 800
1%
100
All
Immedi-
ately
8E
PnB1C
4
Zero Speed Detec-
tion Range
1,000 to
10,000,000
10
-3
min
-1
20000
All
Immedi-
ately
8F
PnB1E
4
Speed Match Signal
Detection Range
0 to 100,000
10
-3
min
-1
10000
All
Immedi-
ately
90
PnB20
4
SVCMD_ CTRL bit
Enabled/Disabled
(read only)
−
−
0FFF3F3F
h
All
−
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting Range
Setting Unit
[Resolution]
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
0000h to
0009h
The settings are the same as those for SEL_MON Monitor Selection 1.
Bit 0
CMD_PAUSE (1: Enabled)
Bit 1
CMD_CANCEL (1: Enabled)
Bits 2 and 3
STOP_MODE (1: Enabled)
Bits 4 and 5
ACCFIL (1: Enabled)
Bits 6 and 7
Reserved (0: Disabled).
Bit 8
LT_REQ1 (1: Enabled)
Bit 9
LT_REQ2 (1: Enabled)
Bits 10 and 11
LT_SEL1 (1: Enabled)
Bits 12 and 13
LT_SEL2 (1: Enabled)
Bits 14 and 15
Reserved (0: Disabled).
Bits 16 to 19
SEL_MON1 (1: Enabled)
Bits 20 to 23
SEL_MON2 (1: Enabled)
Bits 24 to 27
SEL_MON3 (1: Enabled)
Bits 28 to 31
Reserved (0: Disabled).
Содержание SGD7S-R70A20A023F40B
Страница 52: ...3 7 Monitoring 3 23...