6.2 FT40 Specification
6.2.3 Parameter Recording Table
6-62
Pn507
100
Brake Reference Output
Speed Level
Immediately
Pn508
50
Servo OFF-Brake Com-
mand Waiting Time
Immediately
Pn509
20
Momentary Power Interrup-
tion Hold Time
Immediately
Pn50A
1881h
Input Signal Selections 1
After restart
Pn50B
8882h
Input Signal Selections 2
After restart
Pn50E
0000h
Output Signal Selections 1
After restart
Pn50F
0100h
Output Signal Selections 2
After restart
Pn510
0000h
Output Signal Selections 3
After restart
Pn511
6543h
Input Signal Selections 5
After restart
Pn512
0000h
Output Signal Inverse Set-
tings
After restart
Pn514
0000h
Output Signal Selections 4
After restart
Pn516
8888h
Input Signal Selections 7
After restart
Pn51B
1000
Motor-Load Position Devia-
tion Overflow Detection
Level
Immediately
Pn51E
100
Position Deviation Over-
flow Warning Level
Immediately
Pn520
5242880
Position Deviation Over-
flow Alarm Level
Immediately
Pn522
7
Positioning Completed
Width
Immediately
Pn524
1073741824
Near Signal Width
Immediately
Pn526
5242880
Position Deviation Over-
flow Alarm Level at Servo
ON
Immediately
Pn528
100
Position Deviation Over-
flow Warning Level at Servo
ON
Immediately
Pn529
10000
Speed Limit Level at Servo
ON
Immediately
Pn52A
20
Multiplier per Fully-closed
Rotation
Immediately
Pn52B
20
Overload Warning Level
Immediately
Pn52C
100
Base Current Derating at
Motor Overload Detection
After restart
Pn530
0000h
Program Jogging-Related
Selections
Immediately
Pn531
32768
Program Jogging Travel
Distance
Immediately
Pn533
500
Program Jogging Move-
ment Speed
Immediately
Pn534
100
Program Jogging Accelera-
tion/Deceleration Time
Immediately
Pn535
100
Program Jogging Waiting
Time
Immediately
Pn536
1
Program Jogging Number
of Movements
Immediately
Pn550
0
Analog Monitor 1 Offset
Voltage
Immediately
Pn551
0
Analog Monitor 2 Offset
Voltage
Immediately
Continued on next page.
Continued from previous page.
Parameter
No.
Default Setting
Name
When
Enabled
Содержание SGD7S-R70A20A023F40B