6.2 FT40 Specification
6.2.2 List of MECHATROLINK-III Common Parameters
6-50
44
PnA88
4
Position Base Unit
(Set the value of n
from the following
formula: Position unit
(43 PnA86) × 10
n
)
0
−
0
All
After
restart
Un
it sett
ing
s
45
PnA8A
4
Acceleration Unit
0h
−
0h
All
After
restart
46
PnA8C
4
Acceleration Base
Unit
(Set the value of n
from the following
formula: Acceleration
unit (45 PnA8A) ×
10
n
)
4 to 6
−
4
All
After
restart
47
PnA8E
4
Torque Unit
1h or 2h
−
1h
All
After
restart
48
PnA90
4
Torque Base Unit
*5
(Set the value of n
from the following
formula: Torque unit
(47 PnA8E)
×
10
n
)
-5 to 0
−
0
All
After
restart
49
PnA92
4
Supported Unit (read
only)
−
−
0601011F
h
All
−
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting Range
Setting Unit
[Resolution]
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
0000h
Reference units/s
2
0001h
Percentage (%) of rated torque
0002h
Maximum torque/40000000h
*5
Speed Units
Bit 0
Reference units/s (1: Enabled)
Bit 1
Reference units/min (1: Enabled)
Bit 2
Percentage (%) of rated speed (1: Enabled)
Bit 3
min
-1
(rpm) (1: Enabled)
Bit 4
Maximum motor speed/4000000h (1: Enabled)
Bits 5 to 7
Reserved (0: Disabled).
Position Units
Bit 8
Reference units (1: Enabled)
Bits 9 to 15
Reserved (0: Disabled).
Acceleration Units
Bit 16
Reference units/s
2
(1: Enabled)
Bit 17
ms (acceleration time required to reach rated speed) (0: Disabled)
Bits 18 to 23
Reserved (0: Disabled).
Torque Units
Bit 24
N
m (0: Disabled)
Bit 25
Percentage (%) of rated torque (1: Enabled)
Bit 26
Maximum torque/40000000h
Bits 27 to 31
Reserved (0: Disabled).