6.2 FT40 Specification
6.2.1 List of Servo Parameters
6-22
Pn452
2
Pressure Feedback
Control 1 Pressure
Feedback Loop Propor-
tional Gain 2
0 to 10,000
1%
100
All
Immedi-
ately
Setup
Pn456
2
Sweep Torque Refer-
ence Amplitude
1 to 800
1%
15
All
Immedi-
ately
Tuning
*1
Pn458
2
Pressure Feedback
Selection Switch 2
0000h to
0011h
–
0011h
All
After
restart
Setup
Pn459
2
Gravity Compensation
Reference Level for
Torque Control
0 to 10,000
0.01%
500
All
Immedi-
ately
Setup
–
Pn45A
2
Pressure Feedback Dis-
able Level
0 to 10,000
0.01%
1000
All
Immedi-
ately
Setup
Pn45B
2
Reserved parameter (Do
not change.)
–
–
50
All
–
–
–
Pn45C
2
Reserved parameter (Do
not change.)
–
–
150
All
–
–
–
Pn45D
2
Reserved parameter (Do
not change.)
–
–
100
All
–
–
–
Pn45E
2
Pressure Feedback Ref-
erence Filter Time Con-
stant
0 to 65,535
0.01 ms
0
All
Immedi-
ately
Setup
–
Pn460
2
Notch Filter Adjustment
Selections 1
0000h to
0101h
–
0101h
All
Immedi-
ately
Tuning
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Pressure Feedback Control Mode Selection Switch
0
Set mode 1.
1
Set mode 2.
n.
X
Pressure Feedback Type Selection Switch
0
Set pressure feedback control 1.
1
Set pressure feedback control 2.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Notch Filter Adjustment Selection 1
0
Do not adjust the first stage notch filter automatically during execution of auto-
tuning without a host reference, autotuning with a host reference, and custom
tuning.
1
Adjust the first stage notch filter automatically during execution of autotuning
without a host reference, autotuning with a host reference, and custom tuning.
n.
X
Reserved parameter (Do not change.)
n.
X
Notch Filter Adjustment Selection 2
0
Do not adjust the second stage notch filter automatically during execution of
autotuning without a host reference, autotuning with a host reference, and
custom tuning.
1
Adjust the second stage notch filter automatically during execution of autotun-
ing without a host reference, autotuning with a host reference, and custom
tuning.
n.X
Reserved parameter (Do not change.)