Output area
Offset
Size
Area
Description
0
2
Drive 1
‘0x8100-01 - Control word’ on page 109
2
2
Drive 1
‘0x8280-01 - Operating mode requested’ on page 118
4
4
Drive 1
‘0x8400-02 - Positioning profile target position’ on page 123
8
4
Drive 1
‘0x8400-03 - Positioning profile target velocity’ on page 123
12
4
Drive 1
‘0x8400-04 - Positioning profile target acceleration’ on page 124
16
4
Drive 1
‘0x8400-05 - Positioning profile target deceleration’ on page 124
20
2
Drive 1
The assignment depends on the selected operating modes
n
Torque control enabled
–
‘0x8600-03 - Current set value’ on page 132
n
Torque control disabled
–
‘0x8600-04 - Current limit positive direction’ on page 133
respectively
‘0x8600-05 - Current limit negative direction’ on page 133
22
2
-
reserved
24
2
Drive 2
‘0x8100-01 - Control word’ on page 109
*
26
2
Drive 2
‘0x8280-01 - Operating mode requested’ on page 118
*
28
4
Drive 2
‘0x8400-02 - Positioning profile target position’ on page 123
32
4
Drive 2
‘0x8400-03 - Positioning profile target velocity’ on page 123
*
36
4
Drive 2
‘0x8400-04 - Positioning profile target acceleration’ on page 124
*
40
4
Drive 2
‘0x8400-05 - Positioning profile target deceleration’ on page 124
44
2
Drive 2
The assignment depends on the selected operating modes
n
Torque control enabled
–
‘0x8600-03 - Current set value’ on page 132
*
n
Torque control disabled
–
‘0x8600-04 - Current limit positive direction’ on page 133
respectively
‘0x8600-05 - Current limit negative direction’ on page 133
46
2
-
reserved
48
1
-
reserved
49
1
Drive
‘0x7200-06 - Digital output states I/O1...I/O4 requested states’ on page 108
50
1
Acyclic
Acyclic communication channel:
Command
51
1
Acyclic
Acyclic communication channel:
Subindex in the object dictionary
52
2
Acyclic
Acyclic communication channel:
Index in the object dictionary
54
4
Acyclic
Acyclic communication channel:
Data
58
1
-
reserved
VIPA System SLIO
Deployment
In-/Output area
HB300 | FM | 054-1CB00 | en | 18-06
85