4.5.1 Homing by means of a homing switch
n
Homing can only be accessed from the
PtP positioning profile
mode.
n
The
target position
is the reference position, which is maximally moved to. This is to
be specified with sign.
n
The homing happens according to the following steps:
–
It is traversed with the high
velocity V1
toward the target position
T
until the
homing switch
R
is overrun.
–
Then it is decelerated and traversed in the opposite direction with
velocity V1
.
–
If the homing value
R
is overrun again, it is again decelerated and it is again
accelerated in the positive direction with slower
velocity V2
.
–
With the next overrun of the homing switch the reference position
R
is set and
moved to with
velocity V2
.
n
Use To connect the home switch one of the digital inputs of the motion module and
specify the polarity of the switch with the parametrization.
V
1
High velocity
V
2
Low velocity
R Homing switch respectively homing value
T Target position
L
General position limit
Homing by means of a
homing switch
VIPA System SLIO
Deployment
Homing > Homing by means of a homing switch
HB300 | FM | 054-1CB00 | en | 18-06
55