1.
Chapter 4.2 ‘Commissioning’ on page 47
Homing objects
Chapter 5.2.11 ‘Homing - 0x8300’ on page 119
2.
n
Switch the state machine to state
‘Switch on disabled’
–
Send the command "Disable voltage"
‘0x8100-01 - Control word’ on page 109
Bit 3...0: xx0x:
ð
The motion module shows the state
‘Switch on disabled’
.
3.
n
‘0x8400-03 - Positioning profile target velocity’ on page 123
–
Enter the value 0.
4.
n
Switch your motion module to the
Positioning
Operating mode requested’ on page 118
–
Enter the value 1.
5.
Set the following parameters:
n
‘0x8300-02 - Homing method’ on page 119
–
Enter the value -1 for homing by means of current limitation.
n
‘0x8600-04 - Current limit positive direction’ on page 133
‘0x8600-05 - Current limit negative direction’ on page 133
–
Specify the limit currents.
n
‘0x8300-05 - Homing target position’ on page 121
–
Define by specifying a target position the maximum axis movement path,
that during movement the soft stop is hit.
n
‘0x8300-06 - Homing velocity V1’ on page 121
–
Specify the high velocity for the movement to the soft stop.
n
‘0x8300-07 - Homing velocity V2’ on page 121
–
Specify the low velocity for the free movement from the soft stop.
n
‘0x8300-08 - Homing acceleration’ on page 122
–
Specify the acceleration for homing.
n
‘0x8300-09 - Homing deceleration’ on page 122
–
Specify the deceleration for homing.
n
‘0x8300-10 - Homing offset value’ on page 122
–
If necessary specify an offset for the homing position.
6.
Send the command "Shutdown"
‘0x8100-01 - Control word’ on page 109
Bit 3...0: x110:
ð
The motion module shows the state
‘Ready to switch on’
.
7.
Send the command "Switch on".
‘0x8100-01 - Control word’ on page 109
Bit 3...0: 0111
ð
The motion module shows the state
‘Switched on’
.
8.
Send the command "Enable operation".
‘0x8100-01 - Control word’ on page 109
Bit 3...0: 1111
ð
The motion module shows the state
‘Operation enabled’
. The drive is now
ready for your move commands.
9.
n
Switch your motion module to the
Homing
mode.
Operating mode requested’ on page 118
–
Enter the value 6.
ð
The drive starts homing. Upon completion of the homing, the position of the soft
stop is used as the reference point. The motion module then automatically
switches back to the
Positioning
mode.
Proceeding
VIPA System SLIO
Deployment
Homing > Homing by means of current limitation
HB300 | FM | 054-1CB00 | en | 18-06
59