Order no.
054-1CB00
Cable length, unshielded
600 m
Rated load voltage
DC 20.4...28.8 V
Reverse polarity protection of rated load voltage
-
Current consumption from load voltage L+ (without load)
-
Output current at signal "1", rated value
500 mA
Output delay of "0" to "1"
1.5 ms
Output delay of "1" to "0"
1.5 ms
Minimum load current
-
Lamp load
10 W
Parallel switching of outputs for redundant control of a load not possible
Parallel switching of outputs for increased power
not possible
Actuation of digital input
ü
Switching frequency with resistive load
max. 300 Hz
Switching frequency with inductive load
max. 0.5 Hz
Switching frequency on lamp load
max. 10 Hz
Internal limitation of inductive shut-off voltage
L+ (-45 V)
Short-circuit protection of output
yes, electronic
Trigger level
1 A
Number of operating cycle of relay outputs
-
Switching capacity of contacts
-
Output data size
-
Status information, alarms, diagnostics
Status display
green LED per channel
Interrupts
yes, parameterizable
Process alarm
no
Diagnostic interrupt
yes, parameterizable
Diagnostic functions
yes
Diagnostics information read-out
possible
Supply voltage display
green LED
Group error display
red LED
Channel error display
red LED per channel
Isolation
Between channels
-
Between channels of groups to
-
Between channels and backplane bus
ü
Insulation tested with
AC 500 V
VIPA System SLIO
Hardware description
Technical data
HB300 | FM | 054-1CB00 | en | 18-06