In addition to the control parameters you have to specify the data from your application,
consisting of the nominal drive data and scaling.
‘0x8180-02 - Gear factor’ on page 116
à
Application data
‘0x8C00-04 - Motor max. current’ on page 141
‘0x8C00-06 - Motor nominal velocity’ on page 141
4.5 Homing
Here you will find information on how the System SLIO motion module searches the
refer-
ence position
. The reference position is also called "basic position", "start position" or
"home position".
Homing
is an initialisation drive of a drive, where the correct position is
determined by means of an reference signal. This process is called "referencing", "home
drive" or "homing".
When referencing you can determine velocity, acceleration, deceleration and type of
homing. The FM 054-1CB00 supports the following homing types:
n
Chapter 4.5.1 ‘Homing by means of a homing switch’ on page 55
n
Chapter 4.5.2 ‘Homing to current position’ on page 57
n
Chapter 4.5.3 ‘Homing by means of current limitation’ on page 58
Application data
Overview
VIPA System SLIO
Deployment
Homing
HB300 | FM | 054-1CB00 | en | 18-06