4.2 Commissioning
4.2.1 Installation
1.
Build your System SLIO and connect it.
Chapter 2 ‘Basics and mounting’
.
2.
Connect your drive.
Chapter 4.3 ‘Connecting a motor’ on page 49
4.2.2 Inspections and tests before the test operation
Please check the following items, and take appropriate measures in the event of an error,
before you start the test operation.
n
Are all wiring and connections correct?
n
Are all nuts and bolts at the drive properly tightened?
n
For a motor with oil seal: Is the seal not damaged and is the motor lubricated? Please
always regard the start-up instructions of your motor!
4.2.3 Start-up of the System SLIO motion module
Please check the following items, and take appropriate measures in the event of an error,
before you start the test operation.
n
Check the correct setting of the set points for the drive and the I/O signals from the
superordinate control.
n
Check wiring between the superordinate control and your drive as well as the polarity
of the wires.
n
Check all operational settings of your drive.
Set the respective system limits, the system behavior and characteristics in the object dic-
tionary via the
Acyclic channel
n
Behaviour at quick stop and on error
n
Motor maximum current
‘0x8C00-04 - Motor max. current’ on page 141
n
Current limits
‘0x8600-04 - Current limit positive direction’ on page 133
‘0x8600-05 - Current limit negative direction’ on page 133
n
Velocity limit values
n
Position limitations
n
Assignment of the digital inputs and outputs
Preparation
Preparation
Setting the limits
VIPA System SLIO
Deployment
Commissioning > Start-up of the System SLIO motion module